General Information
Revision date
2015-07-27
Product name
Germane (12.44% - 62.19) in Hydrogen
1.2.1 Relevant identified uses
Semiconductors
Emergency telephone
1-800-424-9300
Icons in SDS
Company Information
company name
Air Liquide
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H220, H280, H331, H370
Hazard statements
Code
Statements
H220
Extremely flammable gas
Section 2
Classification (GHS-US)
Flam. Gas 1 H220 Compressed gas H280 Acute Tox. 3 (Inhalation:gas) H331 STOT SE 1 H370
Hazard statements
see section 16 : H220 - Extremely flammable gas H280 - Contains gas under pressure; may explode if heated H331 - Toxic if inhaled H370 - Causes damage to organs (blood, kidneys, liver) (Inhalation) CGA-HG04 - May form explosive mixtures with air CGA-HG11 - Symptoms may be delayed
2.2 Label elements
GHS-US labeling
Hazard pictograms
GHS02 GHS04 GHS06 GHS08
Signal word
Danger
Precautionary statements
P202 - Do not handle until all safety precautions have been read and understood P210 - Keep away from heat, hot surfaces, open flames, sparks. - No smoking P260 - Do not breathe gas P271 - Use only outdoors or in a well-ventilated area P280 - Wear eye protection, face protection, protective gloves, protective clothing P284 - Wear respiratory protection. Consult respiratory device supplier´s product information for the selection of the appropriate device. P304+P340 - If inhaled: Remove person to fresh air and keep comfortable for breathing P307+P311 - If exposed: Call a poison center/doctor P377 - Leaking gas fire: Do not extinguish, unless leak can be stopped safely P381 - Eliminate all ignition sources if safe to do so P403 - Store in a well-ventilated place P405 - Store locked up P501 - Dispose of contents/container in accordance with local/regional/national/international regulations CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F) CGA-PG05 - Use a back flow preventive device in the piping 07/27/2015 EN (English US) CGA-PG06 - Close valve after each use and when empty CGA-PG10 - Use only with equipment rated for cylinder pressure CGA-PG14 - Approach suspected leak area with caution CGA-PG18 - When returning cylinder, install leak tight valve outlet cap or plug CGA-PG21 - Open valve slowly
2.3 Other hazards
No additional information available 2.4.
Ingredient(s) with unknown acute toxicity
Not applicable