GHS03 GHS04
Health risk rating 2
Safety risk rating 4
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

7440-59-7

Name of the chemical

Helium He

Concentration

0.01-

General Information

Version

1.0

Revision date

2017-10-10

Product name

Oxygen (23.51% - 99.99%) in Helium

supplier name

Air Liquide Canada Inc

Emergency telephone

514-878-1667

Icons in SDS

GHS03 GHS04 T011 T018 T026

Company Information

company name

Air Liquide Canada Inc

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H270, H280

Hazard statements

Code

Statements

H270

May cause or intensify fire; oxidiser

Section 2

SECTION 2: Hazards identification

WHMIS Classification

Oxidising Gases, Category 1 H270 Gases under pressure : Compressed gas H280

Hazard statements

see section 16 : H270 - May cause or intensify fire; oxidiser. H280 - Contains gas under pressure; may explode if heated.

2.2 Label elements

GHS-CA labelling

Hazard pictograms

GHS03 GHS04

Signal word

Danger

Precautionary statements

P370+P376 - In case of fire: Stop leak if safe to do so P501 - Dispose of contents/container in accordance with local/regional/national/international regulations. P403 - Store in a well-ventilated place. P220 - Keep away from clothing and other combustible materials. P244 - Keep valves and fittings free from oil and grease. P202 - Do not handle until all safety precautions have been read and understood. P280 - Wear eye protection, face protection, protective clothing, protective gloves. P271 - Use only outdoors or in a well-ventilated area. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52 °C/125 °F CGA-PG05 - Use a back flow preventive device in the piping CGA-PG06 - Close valve after each use and when empty CGA-PG10 - Use only with equipment rated for cylinder pressure CGA-PG14 - Approach suspected leak area with caution CGA-PG20 - Use only with equipment of compatible materials of construction and rated for cylinder pressure CGA-PG21 - Open valve slowly CGA-PG22 - Use only with equipment cleaned for oxygen service

2.3 Other hazards

No additional information available 2.4.

Ingredient(s) with unknown acute toxicity

No data available 10/11/2017 EN (English) Page 1

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.