Connection Unit with Regulator 1/4in, Part Number CP7994

Agilent Technologies Manufacturing GmbH & Co. KG

Revision date : 2018-11-09

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS07 GHS08 GHS09
Health risk rating 5
Safety risk rating 1
Environmental risk rating 4

Note: Ingredients listed on restricted chemical lists

EC/CAS

1344-28-1

Name of the chemical

aluminium oxide

Concentration

N/A

EC/CAS

1317-38-0

Name of the chemical

Copper (II) oxide

Concentration

N/A

EC/CAS

1313-13-9

Name of the chemical

Manganese dioxide

Concentration

N/A

Listed in

EC/CAS

14808-60-7

Name of the chemical

Silica, crystalline

Concentration

N/A

EC/CAS

14464-46-1

Name of the chemical

Cristobalit (s. u. TRGS 906)

Concentration

N/A

EC/CAS

231-153-3

Name of the chemical

Carbon black

Concentration

N/A

EC/CAS

215-215-7

Name of the chemical

Nickel monoxide

Concentration

N/A

EC/CAS

238-878-4

Name of the chemical

Quarz-A-Staub (s. u. TRGS 906)

Concentration

N/A

EC/CAS

238-455-4

Name of the chemical

Cristobalit (s. u. TRGS 906)

Concentration

N/A

General Information

Revision date

2018-11-09

Product name

Connection Unit with Regulator 1/4in, Part Number CP7994

Product Synonyms

Hydrocarbon

Icons in SDS

Company Information

company name

Agilent Technologies Manufacturing GmbH & Co. KG

e-mail address of the competent person responsible for the Safety Data Sheet

pdl-msds_author@agilent.com

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H332, H350, H373, H400, H411

Hazard statements

Code

Statements

H332

Harmful if inhaled

H350

May cause cancer

H373

May cause damage to organs through prolonged or repeated exposure

H400

Very toxic to aquatic life

H411

Toxic to aquatic life with long lasting effects

Section 2

SECTION 2: Hazards identification

Classification according to Regulation (EC) No. 1272/2008 [CLP/GHS]] This article, when used under reasonable conditions and in accordance with the directions for use, should not present a health hazard. The substance or mixture is encapsulated in the article. Only if released due to use or processing of the article in a manner not in accordance with the product’s directions for use it may present potential health and safety hazards.

Product definition

Gas Clean Filter Mono-constituent substance (encapsulated in article) Hydrocarbon Gas Clean Filter Oxygen Mixture (encapsulated in article) Gas Clean Filter Moisture Mixture (encapsulated in article)

CLP CLASSIFICATION

Gas Clean Filter Oxygen H332 ACUTE TOXICITY (inhalation) - Category 4 H350 CARCINOGENICITY - Category 1A H400 SHORT-TERM (ACUTE) AQUATIC HAZARD - Category 1 H411 LONG-TERM (CHRONIC) AQUATIC HAZARD - Category 2 Gas Clean Filter Moisture H373 SPECIFIC TARGET ORGAN TOXICITY - REPEATED EXPOSURE - Category 2 Ingredients of unknown : Gas Clean Filter Oxygen Percentage of the mixture consisting of ingredient(s) of toxicity unknown inhalation toxicity: > 60% Gas Clean Filter Moisture Percentage of the mixture consisting of ingredient(s) of unknown dermal toxicity: > 60% Percentage of the mixture consisting of ingredient(s) of unknown inhalation toxicity: > 60% Percentage of the mixture consisting of ingredient(s) of unknown oral toxicity: > 60% Ingredients of unknown : Gas Clean Filter Moisture Percentage of the mixture consisting of ingredient(s) of ecotoxicity unknown hazards to the aquatic environment: 100% See Section 16 for the full text of the H statements declared above. See Section 11 for more detailed information on health effects and symptoms.

Hazard pictograms

Gas Clean Filter Oxygen Gas Clean Filter Moisture

Signal word

Gas Clean Filter No signal word. Hydrocarbon Gas Clean Filter Oxygen Danger Gas Clean Filter Moisture Warning

Hazard statements

Gas Clean Filter No known significant effects or critical hazards. Hydrocarbon Gas Clean Filter Oxygen H332 - Harmful if inhaled. H350 - May cause cancer. H400 - Very toxic to aquatic life. H411 - Toxic to aquatic life with long lasting effects. Gas Clean Filter Moisture H373 - May cause damage to organs through prolonged or repeated exposure.

Prevention

Gas Clean Filter Not applicable. Hydrocarbon Gas Clean Filter Oxygen P201 - Obtain special instructions before use. P280 - Wear protective gloves. Wear protective clothing. Wear eye or face protection. P273 - Avoid release to the environment. Gas Clean Filter Moisture P260 - Do not breathe dust.

Response

Gas Clean Filter Not applicable. Hydrocarbon Gas Clean Filter Oxygen P304 + P340 + P312 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER or physician if you feel unwell. Gas Clean Filter Moisture P314 - Get medical attention if you feel unwell.

Storage

Gas Clean Filter Not applicable. Hydrocarbon Gas Clean Filter Oxygen P405 - Store locked up. Gas Clean Filter Moisture Not applicable.

Disposal

Gas Clean Filter Not applicable. Hydrocarbon Gas Clean Filter Oxygen P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations. Gas Clean Filter Moisture P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations.

Hazardous Ingredients

Gas Clean Filter Oxygen - manganese dioxide - nickel monoxide Gas Clean Filter Moisture - crystalline silica, respirable powder - cristobalite

Supplemental label elements

Gas Clean Filter Not applicable. elements Hydrocarbon Gas Clean Filter Oxygen Contains nickel monoxide. May produce an allergic reaction. Gas Clean Filter Moisture Not applicable. Annex XVII - Restrictions : Gas Clean Filter Not applicable. on the manufacture, Hydrocarbon placing on the market Gas Clean Filter Oxygen Restricted to professional users. and use of certain Gas Clean Filter Moisture Not applicable. dangerous substances, mixtures and articles

Special packaging requirements

Tactile warning of Gas Clean Filter Not applicable. danger Hydrocarbon Gas Clean Filter Oxygen Not applicable. Gas Clean Filter Moisture Not applicable.

2.3 Other hazards

Other hazards which do : Gas Clean Filter May form explosible dust-air mixture if dispersed. not result in Hydrocarbon

2.1 Classification of the substance or mixture

Gas Clean Filter Oxygen None known. Gas Clean Filter Moisture None known.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.