Infection Detection Panel I, Part Number 8929000

Agilent Technologies LDA UK Ltd

Revision date : 2021-11-25

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS07 GHS08
Health risk rating 5
Safety risk rating 1
Environmental risk rating 3

Note: Ingredients listed on restricted chemical lists

EC/CAS

203-872-2/111-46-6

Name of the chemical

diethyleneglycol

Concentration

≥25-≤50

EC/CAS

200-001-8/50-00-0

Name of the chemical

Formaldehyde

Concentration

≤10

EC/CAS

247-852-1/26628-22-8

Name of the chemical

Sodium Azide

Concentration

≤1

General Information

Revision date

2021-11-25

Product name

Infection Detection Panel I, Part Number 8929000

Emergency telephone

+(44)-870-8200418

Icons in SDS

GHS07 GHS08

Company Information

company name

Agilent Technologies LDA UK Ltd

e-mail address of the competent person responsible for the Safety Data Sheet

pdl-msds_author@agilent.com

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H302, H302+H332, H315, H317, H319, H332, H335, H341, H350, H412

Hazard statements

Code

Statements

H302

Harmful if swallowed

Section 2

SECTION 2: Hazards identification

Classification according to Regulation (EC) No. 1272/2008 [CLP/GHS]]

Product definition

FITC Mouse anti-human Mixture CD14 PE Mouse anti-human Mixture CD64 PerCP Mouse anti- Mixture human CD45 APC Mouse anti-human Mixture HLA-DR Lysing solution Mixture

CLP CLASSIFICATION

FITC Mouse anti- human CD14 H412 LONG-TERM (CHRONIC) AQUATIC HAZARD Category 3 PE Mouse anti- human CD64 H412 LONG-TERM (CHRONIC) AQUATIC HAZARD Category 3 PerCP Mouse anti- human CD45 H412 LONG-TERM (CHRONIC) AQUATIC HAZARD Category 3 APC Mouse anti- human HLA-DR H412 LONG-TERM (CHRONIC) AQUATIC HAZARD Category 3 Lysing solution H302 ACUTE TOXICITY (oral) Category 4 H332 ACUTE TOXICITY (inhalation) Category 4 H315 SKIN CORROSION/IRRITATION Category 2 H319 SERIOUS EYE DAMAGE/EYE IRRITATION Category 2 H317 SKIN SENSITISATION Category 1 H341 GERM CELL MUTAGENICITY Category 2 H350 CARCINOGENICITY Category 1B H335 SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE Category 3 (Respiratory tract irritation) Ingredients of unknown : Lysing solution Percentage of the mixture consisting of ingredient(s) of toxicity unknown acute dermal toxicity: 1 - 10% Percentage of the mixture consisting of ingredient(s) of unknown acute inhalation toxicity: 30 - 60% Percentage of the mixture consisting of ingredient(s) of unknown acute oral toxicity: 1 - 10% Ingredients of unknown : Lysing solution

Contains

9.9% of components with unknown hazards to the ecotoxicity aquatic environment See Section 16 for the full text of the H statements declared above. See Section 11 for more detailed information on health effects and symptoms.

Hazard pictograms

Lysing solution

Signal word

FITC Mouse anti-human No signal word. CD14 PE Mouse anti-human No signal word. CD64 PerCP Mouse anti- No signal word. human CD45 APC Mouse anti-human No signal word. HLA-DR Lysing solution Danger

Hazard statements

FITC Mouse anti-human H412 - Harmful to aquatic life with long lasting effects. CD14 PE Mouse anti-human H412 - Harmful to aquatic life with long lasting effects. CD64 PerCP Mouse anti- H412 - Harmful to aquatic life with long lasting effects. human CD45 APC Mouse anti-human H412 - Harmful to aquatic life with long lasting effects. HLA-DR Lysing solution H302 + H332 - Harmful if swallowed or if inhaled. H315 - Causes skin irritation. H317 - May cause an allergic skin reaction. H319 - Causes serious eye irritation. H335 - May cause respiratory irritation. H341 - Suspected of causing genetic defects. H350 - May cause cancer.

Prevention

FITC Mouse anti-human P273 - Avoid release to the environment. CD14 PE Mouse anti-human P273 - Avoid release to the environment. CD64 PerCP Mouse anti- P273 - Avoid release to the environment. human CD45 APC Mouse anti-human P273 - Avoid release to the environment. HLA-DR Lysing solution P201 - Obtain special instructions before use. P280 - Wear protective gloves, protective clothing, eye protection, face protection, or hearing protection. P261 - Avoid breathing vapour.

Response

FITC Mouse anti-human Not applicable. CD14 PE Mouse anti-human Not applicable. CD64 PerCP Mouse anti- Not applicable. human CD45 APC Mouse anti-human Not applicable. HLA-DR Lysing solution P308 + P313 - IF exposed or concerned: Get medical advice or attention.

Storage

FITC Mouse anti-human Not applicable. CD14 PE Mouse anti-human Not applicable. CD64 PerCP Mouse anti- Not applicable. human CD45 APC Mouse anti-human Not applicable. HLA-DR Lysing solution P403 + P233 - Store in a well-ventilated place. Keep container tightly closed.

Disposal

FITC Mouse anti-human P501 - Dispose of contents and container in accordance CD14 with all local, regional, national and international regulations. PE Mouse anti-human P501 - Dispose of contents and container in accordance CD64 with all local, regional, national and international regulations. PerCP Mouse anti- P501 - Dispose of contents and container in accordance human CD45 with all local, regional, national and international regulations. APC Mouse anti-human P501 - Dispose of contents and container in accordance HLA-DR with all local, regional, national and international regulations. Lysing solution P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations.

Hazardous Ingredients

FITC Mouse anti-human Not applicable. CD14 PE Mouse anti-human Not applicable. CD64 PerCP Mouse anti- Not applicable. human CD45 APC Mouse anti-human Not applicable. HLA-DR Lysing solution - 2,2' -oxybisethanol - formaldehyde

Supplemental label elements

FITC Mouse anti-human Not applicable. elements CD14 PE Mouse anti-human Not applicable. CD64 PerCP Mouse anti- Not applicable. human CD45 APC Mouse anti-human Not applicable. HLA-DR Lysing solution Not applicable. Annex XVII - Restrictions : FITC Mouse anti-human Not applicable. on the manufacture, CD14 placing on the market PE Mouse anti-human Not applicable. and use of certain CD64 dangerous substances, PerCP Mouse anti- Not applicable. mixtures and articles human CD45 APC Mouse anti-human Not applicable. HLA-DR Lysing solution Restricted to professional users.

Special packaging requirements

Tactile warning of FITC Mouse anti-human Not applicable. danger CD14 PE Mouse anti-human Not applicable. CD64 PerCP Mouse anti- Not applicable. human CD45 APC Mouse anti-human Not applicable. HLA-DR Lysing solution Not applicable.

2.3 Other hazards

Product meets the : FITC Mouse anti-human This mixture does not contain any substances that are criteria for PBT or vPvB CD14 assessed to be a PBT or a vPvB. according to PE Mouse anti-human This mixture does not contain any substances that are Regulation (EC) No. CD64 assessed to be a PBT or a vPvB. 1907/2006, Annex XIII PerCP Mouse anti- This mixture does not contain any substances that are human CD45 assessed to be a PBT or a vPvB. APC Mouse anti-human This mixture does not contain any substances that are HLA-DR assessed to be a PBT or a vPvB. Lysing solution This mixture does not contain any substances that are assessed to be a PBT or a vPvB. Other hazards which do : FITC Mouse anti-human None known. not result in CD14

Classifications

PE Mouse anti-human None known. CD64 PerCP Mouse anti- None known. human CD45 APC Mouse anti-human None known. HLA-DR Lysing solution None known.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs