General Information
Revision date
2020-07-06
Product name
Perchloric Acid 10 percent
CAS No.
7601-90-3
Emergency telephone
1-800-424-9300
Icons in SDS
Company Information
company name
Agilent Technologies, Inc
e-mail address of the competent person responsible for the Safety Data Sheet
SDS@Agilent.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H272, H314, H318, H373
Hazard statements
Code
Statements
H272
May intensify fire; oxidiser
Section 2
2.1 Classification of the substance or mixture
OSHA/HCS status : This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200). H272 OXIDIZING LIQUIDS - Category 2 H314 SKIN CORROSION - Category 1B H318 SERIOUS EYE DAMAGE - Category 1 H373 SPECIFIC TARGET ORGAN TOXICITY (REPEATED EXPOSURE) - Category 2
Signal word
Danger
Hazard statements
H272 - May intensify fire; oxidizer. H314 - Causes severe skin burns and eye damage. H373 - May cause damage to organs through prolonged or repeated exposure. (thyroid)
Prevention
P280 - Wear protective gloves, protective clothing and eye or face protection. P210 - Keep away from heat. No smoking. P220 - Keep away from clothing and other combustible materials. P221 - Take any precaution to avoid mixing with combustibles.
Response
P304 + P310 - IF INHALED: Immediately call a POISON CENTER or doctor.
Storage
Not applicable.
Disposal
P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations.
Supplemental label elements
Keep container tightly closed. Do not breathe vapor or spray. Do not taste or swallow. elements Use only with adequate ventilation. Wash thoroughly after handling.
2.3 Other hazards
Causes respiratory tract burns. Causes digestive tract burns.