Note: Ingredients listed on restricted chemical lists
EC/CAS
108-88-3
Name of the chemical
Toluene
Concentration
≤0.3
General Information
Revision date
2021-01-28
Product name
Operator Training Samples for FID Instruments, Part Number 18801-60700 18801-60700
Emergency telephone
1-800-424-9300
Icons in SDS
Company Information
company name
Agilent Technologies, Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H319, H336, H361, H410
Hazard statements
Code
Statements
H225
Highly Flammable liquid and vapour
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
Flame Ionization Detector Sample A H225 FLAMMABLE LIQUIDS - Category 2 H319 EYE IRRITATION - Category 2A H361 TOXIC TO REPRODUCTION - Category 2 H336 SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) (Narcotic effects) - Category 3 H410 AQUATIC HAZARD (LONG-TERM) - Category 1 Flame Ionization Detector Sample B H225 FLAMMABLE LIQUIDS - Category 2 H319 EYE IRRITATION - Category 2A H361 TOXIC TO REPRODUCTION - Category 2 H336 SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) (Narcotic effects) - Category 3 H410 AQUATIC HAZARD (LONG-TERM) - Category 1
Hazard pictograms
Flame Ionization Detector Sample A Flame Ionization Detector Sample B
Signal word
Flame Ionization Detector Sample Danger A Flame Ionization Detector Sample Danger B
Hazard statements
Flame Ionization Detector Sample H225 - Highly flammable liquid and vapor. A H319 - Causes serious eye irritation. H336 - May cause drowsiness or dizziness. H361 - Suspected of damaging fertility or the unborn child. H410 - Very toxic to aquatic life with long lasting effects. Flame Ionization Detector Sample H225 - Highly flammable liquid and vapor. B H319 - Causes serious eye irritation. H336 - May cause drowsiness or dizziness. H361 - Suspected of damaging fertility or the unborn child. H410 - Very toxic to aquatic life with long lasting effects.
Prevention
Flame Ionization Detector Sample P280 - Wear protective gloves, protective clothing A and eye or face protection. P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P273 - Avoid release to the environment. Flame Ionization Detector Sample P280 - Wear protective gloves, protective clothing B and eye or face protection. P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P273 - Avoid release to the environment.
Response
Flame Ionization Detector Sample P391 - Collect spillage. A Flame Ionization Detector Sample P391 - Collect spillage. B
Storage
Flame Ionization Detector Sample P403 + P235 - Store in a well-ventilated place. A Keep cool. Flame Ionization Detector Sample P403 + P235 - Store in a well-ventilated place. B Keep cool.
Disposal
Flame Ionization Detector Sample P501 - Dispose of contents and container in A accordance with all local, regional, national and international regulations. Flame Ionization Detector Sample P501 - Dispose of contents and container in B accordance with all local, regional, national and international regulations.
Supplemental label elements
Flame Ionization Detector Sample None known. elements A Flame Ionization Detector Sample None known. B
2.3 Other hazards
Flame Ionization Detector Sample None known. A Flame Ionization Detector Sample None known. B