GHS07 GHS08
Health risk rating 4
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

96-49-1

Name of the chemical

ethylene carbonate

Concentration

≥10-≤24

General Information

Revision date

2024-01-16

Product name

IQFISH Probes

1.2.1 Relevant identified uses

For In Vitro Diagnostic Use 0.2 ml IQFISH Probes G111600-85510, G111601-85510, G111602-85510, G111603-85510

Emergency telephone

1-800-424-9300

Icons in SDS

GHS07 GHS08

Company Information

company name

Agilent Technologies, Inc

GHS Information

Signal word

Warning

Hazard Codes

Hazard statements (CLP)

H315, H319, H373

Hazard statements

Code

Statements

H315

Causes skin irritation

Section 2

SECTION 2: Hazards identification

2.1 Classification of the substance or mixture

H315 SKIN IRRITATION - Category 2 H319 EYE IRRITATION - Category 2A H373 SPECIFIC TARGET ORGAN TOXICITY (REPEATED EXPOSURE) - Category 2 Percentage of the mixture consisting of ingredient(s) of unknown hazards to the aquatic

Environmental hazards

18%

Signal word

Warning

Hazard statements

H315 - Causes skin irritation. H319 - Causes serious eye irritation. H373 - May cause damage to organs through prolonged or repeated exposure. (kidneys)

Prevention

P280 - Wear protective gloves. Wear eye or face protection. P260 - Do not breathe vapor. P264 - Wash thoroughly after handling.

Response

P314 - Get medical advice or attention if you feel unwell. P362 + P364 - Take off contaminated clothing and wash it before reuse. P302 + P352 - IF ON SKIN: Wash with plenty of water. P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337 + P313 - If eye irritation persists: Get medical advice or attention.

Storage

Not applicable.

Disposal

P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations.

2.3 Other hazards

None known.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.