General Information
Revision date
2021-12-09
Product name
ICP-MS Stock Tuning Solution, Part Number 5188-6564
1.2.1 Relevant identified uses
Reagents and Standards for Analytical Chemistry Laboratory Use 100 ml Preparation
Emergency telephone
1-800-424-9300
Icons in SDS
Company Information
company name
Agilent Technologies, Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H290, H314, H318, H331, H373
Hazard statements
Code
Statements
H290
May be corrosive to metals
Section 2
SECTION 2: Hazards identification
(29 CFR 1910.1200) Classification of the substance or mixture
Signal word
Danger
Hazard statements
H290 - May be corrosive to metals. H314 - Causes severe skin burns and eye damage. H331 - Toxic if inhaled. H373 - May cause damage to organs through prolonged or repeated exposure. (teeth)
Prevention
P280 - Wear protective gloves, protective clothing and eye or face protection. P234 - Keep only in original packaging. P260 - Do not breathe vapor.
Response
P390 - Absorb spillage to prevent material damage. P304 + P340, P310 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER or doctor. P301 + P310, P330, P331 - IF SWALLOWED: Immediately call a POISON CENTER or doctor. Rinse mouth. Do NOT induce vomiting. P303 + P361 + P353, P310 - IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water. Immediately call a POISON CENTER or doctor. P363 - Wash contaminated clothing before reuse. P305 + P351 + P338, P310 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor.
Storage
Not applicable.
Disposal
P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations.
Supplemental label elements
Do not taste or swallow. Wash thoroughly after handling.
2.3 Other hazards
Causes digestive tract burns.
2.1 Classification of the substance or mixture
OSHA/HCS status : This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200). Classification of the substance or mixture H290 CORROSIVE TO METALS - Category 1 H331 ACUTE TOXICITY (inhalation) - Category 3 H314 SKIN CORROSION - Category 1 H318 SERIOUS EYE DAMAGE - Category 1 H373 SPECIFIC TARGET ORGAN TOXICITY (REPEATED EXPOSURE) - Category 2