General Information
Revision date
2014-06-25
Product name
ICP-MS High Concentration Calcium Standard, Part Number 5190-0480
CAS No.
7697-37-2
Emergency telephone
1-800-424-9300
Icons in SDS
Company Information
company name
Agilent Technologies, Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H314, H318
Hazard statements
Code
Statements
H314
Causes severe skin burns and eye damage
Section 2
2.1 Classification of the substance or mixture
OSHA/HCS status : This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200). H314 SKIN CORROSION - Category 1 H318 SERIOUS EYE DAMAGE - Category 1
Signal word
Danger
Hazard statements
H314 - Causes severe skin burns and eye damage.
Prevention
P280 - Wear protective gloves. Wear eye or face protection. Wear protective clothing. P264 - Wash hands thoroughly after handling.
Response
P304 + P340 + P310 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER or physician. P301 + P310 + P330 + P331 - IF SWALLOWED: Immediately call a POISON CENTER or physician. Rinse mouth. Do NOT induce vomiting. P303 + P361 + P353 + P363 + P310 - IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water or shower. Wash contaminated clothing before reuse. Immediately call a POISON CENTER or physician. P305 + P351 + P338 + P310 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or physician.
Storage
P405 - Store locked up.
Disposal
P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations.
Supplemental label elements
Do not taste or swallow. Wash thoroughly after handling. elements
2.3 Other hazards
Causes digestive tract burns.