Note: Ingredients listed on restricted chemical lists
EC/CAS
247-852-1/26628-22-8
Name of the chemical
Sodium Azide
Concentration
≤1
EC/CAS
9002-93-1
Name of the chemical
Octylphenolethoxylates (OPEO)
Concentration
<10
General Information
Revision date
2022-12-20
Product name
IMT assay (anti-CD71) sample kit, Part Number 8100018 8100018
1.2.2. Uses advised against
Not for use in diagnostic procedures (RUO)
Emergency telephone
+(44)-870-8200418
Icons in SDS
Company Information
company name
Agilent Technologies Deutschland GmbH
e-mail address of the competent person responsible for the Safety Data Sheet
pdl-msds_author@agilent.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H318, H400, H410, H411, H412
Hazard statements
Code
Statements
H318
Causes serious eye damage.
H400
Very toxic to aquatic life
H410
Very toxic to aquatic life with long lasting effects
H411
Toxic to aquatic life with long lasting effects
H412
Harmful to aquatic life with long lasting effects
Section 2
SECTION 2: Hazards identification
1272/2008]
Product definition
Tethering Reagent (anti- Mixture CD71) 10X Tethering Buffer Mixture Cytolysis Reagent Mixture
Hazard pictograms
Cytolysis Reagent
Signal word
Tethering Reagent (anti- No signal word. CD71) 10X Tethering Buffer No signal word. Cytolysis Reagent Danger
Hazard statements
Tethering Reagent (anti- H412 - Harmful to aquatic life with long lasting effects. CD71) 10X Tethering Buffer No known significant effects or critical hazards. Cytolysis Reagent H318 - Causes serious eye damage. H410 - Very toxic to aquatic life with long lasting effects.
Prevention
Tethering Reagent (anti- P273 - Avoid release to the environment. CD71) 10X Tethering Buffer Not applicable. Cytolysis Reagent P280 - Wear eye or face protection. P273 - Avoid release to the environment.
Response
Tethering Reagent (anti- Not applicable. CD71) 10X Tethering Buffer Not applicable. Cytolysis Reagent P391 - Collect spillage. P305 + P351 + P338, P310 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor.
Storage
Tethering Reagent (anti- Not applicable. CD71) 10X Tethering Buffer Not applicable. Cytolysis Reagent Not applicable.
Disposal
Tethering Reagent (anti- P501 - Dispose of contents and container in accordance CD71) with all local, regional, national and international regulations. 10X Tethering Buffer Not applicable. Cytolysis Reagent P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations.
Hazardous Ingredients
Cytolysis Reagent - Polyoxyethylene octyl phenyl ether
Supplemental label elements
Tethering Reagent (anti- Not applicable. elements CD71) 10X Tethering Buffer Not applicable. Cytolysis Reagent Not applicable. Annex XVII - Restrictions : Tethering Reagent (anti- Not applicable. on the manufacture, CD71) placing on the market 10X Tethering Buffer Not applicable. and use of certain Cytolysis Reagent Not applicable. dangerous substances, mixtures and articles
Tactile warning of danger
Tethering Reagent (anti- Not applicable. CD71) 10X Tethering Buffer Not applicable. Cytolysis Reagent Not applicable.
2.3 Other hazards
Product meets the : Tethering Reagent (anti- This mixture does not contain any substances that are criteria for PBT or vPvB CD71) assessed to be a PBT or a vPvB. according to 10X Tethering Buffer This mixture does not contain any substances that are Regulation (EC) No. assessed to be a PBT or a vPvB.
2.1 Classification of the substance or mixture
10X Tethering Buffer None known. Cytolysis Reagent Contains one or more substances considered to have endocrine-disrupting properties. Substances identified Ingredient name Impact as having endocrine disruptor properties Cytolysis Reagent Polyoxyethylene octyl phenyl ether Environment