Note: Ingredients listed on restricted chemical lists
EC/CAS
203-777-6/110-54-3
Name of the chemical
n-Hexan (790/2009)
Concentration
≥90 ≥5%
EC/CAS
200-578-6/64-17-5
Name of the chemical
Ethanol
Concentration
≥90
EC/CAS
202-716-0/98-95-3
Name of the chemical
Nitrobenzene
Concentration
<0.3
EC/CAS
202-425-9/95-50-1
Name of the chemical
1,2-dichlorobenzene
Concentration
≤0.3
General Information
Revision date
2023-08-25
Product name
GC Checkout Standards Kit, Part Number 5188-5358 : 5188-5358
1.2.1 Relevant identified uses
Reagents and Standards for Analytical Chemistry Laboratory Use
Emergency telephone
+(44)-870-8200418
Icons in SDS
Company Information
company name
Agilent Technologies Deutschland GmbH
e-mail address of the competent person responsible for the Safety Data Sheet
pdl-msds_author@agilent.com
GHS Information
Signal word
Flame Ionization
Hazard Codes
Hazard statements (CLP)
H225, H304, H315, H319, H336, H361f, H373, H400, H410, H411, H412
Hazard statements
Code
Statements
H225
Highly flammable liquid and vapour
H304
May be fatal if swallowed and enters airways
H315
Causes skin irritation
H319
Causes serious eye irritation
H336
May cause drowsiness or dizziness
H361f
Suspected of damaging fertility.
H373
May cause damage to organs through prolonged or repeated exposure
H400
Very toxic to aquatic life
H410
Very toxic to aquatic life with long lasting effects
H411
Toxic to aquatic life with long lasting effects
H412
Harmful to aquatic life with long lasting effects
Section 2
SECTION 2: Hazards identification
1272/2008]
Product definition
Flame Ionization Mixture Detector (FID) Sample- 0.33%(w/w) Electron Capture Mixture Detector Sample Nitrogen/Phosphorus Mixture Detector Sample Flame Photometric Mixture Detector Checkout Sample (40) Headspace OQ/PV Mixture Standard
Aspiration hazard
Category 1 H411 LONG-TERM (CHRONIC) AQUATIC HAZARD Category 2 Electron Capture Detector Sample H225 FLAMMABLE LIQUIDS Category 2 H315 SKIN CORROSION/IRRITATION Category 2 H336 SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE Category 3 (Narcotic effects) H304 Category 1 H400 SHORT-TERM (ACUTE) AQUATIC HAZARD Category 1 H410 LONG-TERM (CHRONIC) AQUATIC HAZARD Category 1 Nitrogen/Phosphorus Detector Sample H225 FLAMMABLE LIQUIDS Category 2 H315 SKIN CORROSION/IRRITATION Category 2 H336 SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE Category 3 (Narcotic effects) H304 Category 1 H400 SHORT-TERM (ACUTE) AQUATIC HAZARD Category 1 H410 LONG-TERM (CHRONIC) AQUATIC HAZARD Category 1 Flame Photometric Detector Checkout Sample (40) H225 FLAMMABLE LIQUIDS Category 2 H315 SKIN CORROSION/IRRITATION Category 2 H336 SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE Category 3 (Narcotic effects) H304 Category 1 H400 SHORT-TERM (ACUTE) AQUATIC HAZARD Category 1 H410 LONG-TERM (CHRONIC) AQUATIC HAZARD Category 1 Headspace OQ/PV Standard H225 FLAMMABLE LIQUIDS Category 2 H319 SERIOUS EYE DAMAGE/EYE IRRITATION Category 2 H412 LONG-TERM (CHRONIC) AQUATIC HAZARD Category 3 Flame Ionization Detector (FID) The product is classified as hazardous
Hazard pictograms
Flame Ionization Detector (FID) Sample-0.33%(w/w) Electron Capture Detector Sample Nitrogen/Phosphorus Detector Sample Flame Photometric Detector Checkout Sample (40) Headspace OQ/PV Standard
Signal word
Flame Ionization Danger Detector (FID) Sample- 0.33%(w/w) Electron Capture Danger Detector Sample Nitrogen/Phosphorus Danger Detector Sample Flame Photometric Danger Detector Checkout Sample (40) Headspace OQ/PV Danger Standard
Hazard statements
Flame Ionization H225 - Highly flammable liquid and vapour. Detector (FID) Sample- 0.33%(w/w) H304 - May be fatal if swallowed and enters airways. H315 - Causes skin irritation. H336 - May cause drowsiness or dizziness. H361f - Suspected of damaging fertility. H373 - May cause damage to organs through prolonged or repeated exposure. H411 - Toxic to aquatic life with long lasting effects. Electron Capture H225 - Highly flammable liquid and vapour. Detector Sample H304 - May be fatal if swallowed and enters airways. H315 - Causes skin irritation. H336 - May cause drowsiness or dizziness. H410 - Very toxic to aquatic life with long lasting effects. Nitrogen/Phosphorus H225 - Highly flammable liquid and vapour. Detector Sample H304 - May be fatal if swallowed and enters airways. H315 - Causes skin irritation. H336 - May cause drowsiness or dizziness. H410 - Very toxic to aquatic life with long lasting effects. Flame Photometric H225 - Highly flammable liquid and vapour. Detector Checkout Sample (40) H304 - May be fatal if swallowed and enters airways. H315 - Causes skin irritation. H336 - May cause drowsiness or dizziness. H410 - Very toxic to aquatic life with long lasting effects. Headspace OQ/PV H225 - Highly flammable liquid and vapour. Standard H319 - Causes serious eye irritation. H412 - Harmful to aquatic life with long lasting effects.
Prevention
Flame Ionization P280 - Wear protective gloves, protective clothing and eye Detector (FID) Sample- or face protection. 0.33%(w/w) P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P273 - Avoid release to the environment. Electron Capture P210 - Keep away from heat, hot surfaces, sparks, open Detector Sample flames and other ignition sources. No smoking. P273 - Avoid release to the environment. Nitrogen/Phosphorus P210 - Keep away from heat, hot surfaces, sparks, open Detector Sample flames and other ignition sources. No smoking. P273 - Avoid release to the environment. Flame Photometric P210 - Keep away from heat, hot surfaces, sparks, open Detector Checkout flames and other ignition sources. No smoking. Sample (40) P273 - Avoid release to the environment. Headspace OQ/PV P280 - Wear eye or face protection. Standard P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P273 - Avoid release to the environment.
Response
Flame Ionization P391 - Collect spillage. Detector (FID) Sample- 0.33%(w/w) Electron Capture P391 - Collect spillage. Detector Sample P301 + P310 - IF SWALLOWED: Immediately call a POISON CENTER or doctor. Nitrogen/Phosphorus P391 - Collect spillage. Detector Sample P301 + P310 - IF SWALLOWED: Immediately call a POISON CENTER or doctor. Flame Photometric P391 - Collect spillage. Detector Checkout Sample (40) P301 + P310 - IF SWALLOWED: Immediately call a POISON CENTER or doctor. Headspace OQ/PV P305 + P351 + P338 - IF IN EYES: Rinse cautiously with Standard water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337 + P313 - If eye irritation persists: Get medical advice or attention.
Storage
Flame Ionization P403 + P233 - Store in a well-ventilated place. Keep Detector (FID) Sample- container tightly closed. 0.33%(w/w) Electron Capture P403 + P233 - Store in a well-ventilated place. Keep Detector Sample container tightly closed. Nitrogen/Phosphorus P403 + P233 - Store in a well-ventilated place. Keep Detector Sample container tightly closed. Flame Photometric P403 + P233 - Store in a well-ventilated place. Keep Detector Checkout container tightly closed. Sample (40) Headspace OQ/PV Not applicable. Standard
Disposal
Flame Ionization P501 - Dispose of contents and container in accordance Detector (FID) Sample- with all local, regional, national and international regulations. 0.33%(w/w) Electron Capture P501 - Dispose of contents and container in accordance Detector Sample with all local, regional, national and international regulations. Nitrogen/Phosphorus P501 - Dispose of contents and container in accordance Detector Sample with all local, regional, national and international regulations. Flame Photometric P501 - Dispose of contents and container in accordance Detector Checkout with all local, regional, national and international regulations. Sample (40) Headspace OQ/PV P501 - Dispose of contents and container in accordance Standard with all local, regional, national and international regulations.
Hazardous Ingredients
Flame Ionization n-hexane Detector (FID) Sample- 0.33%(w/w) Electron Capture 2,2,4-trimethylpentane Detector Sample Nitrogen/Phosphorus 2,2,4-trimethylpentane Detector Sample Flame Photometric 2,2,4-trimethylpentane Detector Checkout Sample (40)
Supplemental label elements
Flame Ionization Not applicable. elements Detector (FID) Sample- 0.33%(w/w) Electron Capture Not applicable. Detector Sample Nitrogen/Phosphorus Not applicable. Detector Sample Flame Photometric Not applicable. Detector Checkout Sample (40) Headspace OQ/PV
Contains
1,2-dichlorobenzene. May produce an allergic Standard reaction. Annex XVII - Restrictions : Flame Ionization Not applicable. on the manufacture, Detector (FID) Sample- placing on the market 0.33%(w/w) and use of certain Electron Capture Not applicable. dangerous substances, Detector Sample mixtures and articles Nitrogen/Phosphorus Not applicable. Detector Sample Flame Photometric Not applicable. Detector Checkout Sample (40) Headspace OQ/PV Not applicable. Standard
Special packaging requirements
Tactile warning of : Flame Ionization Not applicable. danger Detector (FID) Sample- 0.33%(w/w) Electron Capture Not applicable. Detector Sample Nitrogen/Phosphorus Not applicable. Detector Sample Flame Photometric Not applicable. Detector Checkout Sample (40) Headspace OQ/PV Not applicable. Standard
2.3 Other hazards
Product meets the : Flame Ionization This mixture does not contain any substances that are criteria for PBT or vPvB Detector (FID) Sample- assessed to be a PBT or a vPvB. according to 0.33%(w/w) Regulation (EC) No. Electron Capture This mixture does not contain any substances that are
2.1 Classification of the substance or mixture
0.33%(w/w) Electron Capture None known. Detector Sample Nitrogen/Phosphorus None known. Detector Sample Flame Photometric None known. Detector Checkout Sample (40) Headspace OQ/PV None known. Standard