GHS07 GHS02 GHS09 GHS08
Health risk rating 4
Safety risk rating 3
Environmental risk rating 5

Note: Ingredients listed on restricted chemical lists

EC/CAS

203-777-6/110-54-3

Name of the chemical

n-Hexan (790/2009)

Concentration

≥90 ≥5%

EC/CAS

200-578-6/64-17-5

Name of the chemical

Ethanol

Concentration

≥90

EC/CAS

202-716-0/98-95-3

Name of the chemical

Nitrobenzene

Concentration

<0.3

EC/CAS

202-425-9/95-50-1

Name of the chemical

1,2-dichlorobenzene

Concentration

≤0.3

General Information

Revision date

2023-08-25

Product name

GC Checkout Standards Kit, Part Number 5188-5358 : 5188-5358

1.2.1 Relevant identified uses

Reagents and Standards for Analytical Chemistry Laboratory Use

Emergency telephone

+(44)-870-8200418

Icons in SDS

GHS02 GHS07 GHS08 GHS09 T050

Company Information

company name

Agilent Technologies Deutschland GmbH

e-mail address of the competent person responsible for the Safety Data Sheet

pdl-msds_author@agilent.com

GHS Information

Signal word

Flame Ionization

Hazard Codes

Hazard statements (CLP)

H225, H304, H315, H319, H336, H361f, H373, H400, H410, H411, H412

Hazard statements

Code

Statements

H225

Highly flammable liquid and vapour

H304

May be fatal if swallowed and enters airways

H315

Causes skin irritation

H319

Causes serious eye irritation

H336

May cause drowsiness or dizziness

H361f

Suspected of damaging fertility.

H373

May cause damage to organs through prolonged or repeated exposure

H400

Very toxic to aquatic life

H410

Very toxic to aquatic life with long lasting effects

H411

Toxic to aquatic life with long lasting effects

H412

Harmful to aquatic life with long lasting effects

Section 2

SECTION 2: Hazards identification

1272/2008]

Product definition

Flame Ionization Mixture Detector (FID) Sample- 0.33%(w/w) Electron Capture Mixture Detector Sample Nitrogen/Phosphorus Mixture Detector Sample Flame Photometric Mixture Detector Checkout Sample (40) Headspace OQ/PV Mixture Standard

Aspiration hazard

Category 1 H411 LONG-TERM (CHRONIC) AQUATIC HAZARD Category 2 Electron Capture Detector Sample H225 FLAMMABLE LIQUIDS Category 2 H315 SKIN CORROSION/IRRITATION Category 2 H336 SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE Category 3 (Narcotic effects) H304 Category 1 H400 SHORT-TERM (ACUTE) AQUATIC HAZARD Category 1 H410 LONG-TERM (CHRONIC) AQUATIC HAZARD Category 1 Nitrogen/Phosphorus Detector Sample H225 FLAMMABLE LIQUIDS Category 2 H315 SKIN CORROSION/IRRITATION Category 2 H336 SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE Category 3 (Narcotic effects) H304 Category 1 H400 SHORT-TERM (ACUTE) AQUATIC HAZARD Category 1 H410 LONG-TERM (CHRONIC) AQUATIC HAZARD Category 1 Flame Photometric Detector Checkout Sample (40) H225 FLAMMABLE LIQUIDS Category 2 H315 SKIN CORROSION/IRRITATION Category 2 H336 SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE Category 3 (Narcotic effects) H304 Category 1 H400 SHORT-TERM (ACUTE) AQUATIC HAZARD Category 1 H410 LONG-TERM (CHRONIC) AQUATIC HAZARD Category 1 Headspace OQ/PV Standard H225 FLAMMABLE LIQUIDS Category 2 H319 SERIOUS EYE DAMAGE/EYE IRRITATION Category 2 H412 LONG-TERM (CHRONIC) AQUATIC HAZARD Category 3 Flame Ionization Detector (FID) The product is classified as hazardous

Hazard pictograms

Flame Ionization Detector (FID) Sample-0.33%(w/w) Electron Capture Detector Sample Nitrogen/Phosphorus Detector Sample Flame Photometric Detector Checkout Sample (40) Headspace OQ/PV Standard

Signal word

Flame Ionization Danger Detector (FID) Sample- 0.33%(w/w) Electron Capture Danger Detector Sample Nitrogen/Phosphorus Danger Detector Sample Flame Photometric Danger Detector Checkout Sample (40) Headspace OQ/PV Danger Standard

Hazard statements

Flame Ionization H225 - Highly flammable liquid and vapour. Detector (FID) Sample- 0.33%(w/w) H304 - May be fatal if swallowed and enters airways. H315 - Causes skin irritation. H336 - May cause drowsiness or dizziness. H361f - Suspected of damaging fertility. H373 - May cause damage to organs through prolonged or repeated exposure. H411 - Toxic to aquatic life with long lasting effects. Electron Capture H225 - Highly flammable liquid and vapour. Detector Sample H304 - May be fatal if swallowed and enters airways. H315 - Causes skin irritation. H336 - May cause drowsiness or dizziness. H410 - Very toxic to aquatic life with long lasting effects. Nitrogen/Phosphorus H225 - Highly flammable liquid and vapour. Detector Sample H304 - May be fatal if swallowed and enters airways. H315 - Causes skin irritation. H336 - May cause drowsiness or dizziness. H410 - Very toxic to aquatic life with long lasting effects. Flame Photometric H225 - Highly flammable liquid and vapour. Detector Checkout Sample (40) H304 - May be fatal if swallowed and enters airways. H315 - Causes skin irritation. H336 - May cause drowsiness or dizziness. H410 - Very toxic to aquatic life with long lasting effects. Headspace OQ/PV H225 - Highly flammable liquid and vapour. Standard H319 - Causes serious eye irritation. H412 - Harmful to aquatic life with long lasting effects.

Prevention

Flame Ionization P280 - Wear protective gloves, protective clothing and eye Detector (FID) Sample- or face protection. 0.33%(w/w) P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P273 - Avoid release to the environment. Electron Capture P210 - Keep away from heat, hot surfaces, sparks, open Detector Sample flames and other ignition sources. No smoking. P273 - Avoid release to the environment. Nitrogen/Phosphorus P210 - Keep away from heat, hot surfaces, sparks, open Detector Sample flames and other ignition sources. No smoking. P273 - Avoid release to the environment. Flame Photometric P210 - Keep away from heat, hot surfaces, sparks, open Detector Checkout flames and other ignition sources. No smoking. Sample (40) P273 - Avoid release to the environment. Headspace OQ/PV P280 - Wear eye or face protection. Standard P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P273 - Avoid release to the environment.

Response

Flame Ionization P391 - Collect spillage. Detector (FID) Sample- 0.33%(w/w) Electron Capture P391 - Collect spillage. Detector Sample P301 + P310 - IF SWALLOWED: Immediately call a POISON CENTER or doctor. Nitrogen/Phosphorus P391 - Collect spillage. Detector Sample P301 + P310 - IF SWALLOWED: Immediately call a POISON CENTER or doctor. Flame Photometric P391 - Collect spillage. Detector Checkout Sample (40) P301 + P310 - IF SWALLOWED: Immediately call a POISON CENTER or doctor. Headspace OQ/PV P305 + P351 + P338 - IF IN EYES: Rinse cautiously with Standard water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337 + P313 - If eye irritation persists: Get medical advice or attention.

Storage

Flame Ionization P403 + P233 - Store in a well-ventilated place. Keep Detector (FID) Sample- container tightly closed. 0.33%(w/w) Electron Capture P403 + P233 - Store in a well-ventilated place. Keep Detector Sample container tightly closed. Nitrogen/Phosphorus P403 + P233 - Store in a well-ventilated place. Keep Detector Sample container tightly closed. Flame Photometric P403 + P233 - Store in a well-ventilated place. Keep Detector Checkout container tightly closed. Sample (40) Headspace OQ/PV Not applicable. Standard

Disposal

Flame Ionization P501 - Dispose of contents and container in accordance Detector (FID) Sample- with all local, regional, national and international regulations. 0.33%(w/w) Electron Capture P501 - Dispose of contents and container in accordance Detector Sample with all local, regional, national and international regulations. Nitrogen/Phosphorus P501 - Dispose of contents and container in accordance Detector Sample with all local, regional, national and international regulations. Flame Photometric P501 - Dispose of contents and container in accordance Detector Checkout with all local, regional, national and international regulations. Sample (40) Headspace OQ/PV P501 - Dispose of contents and container in accordance Standard with all local, regional, national and international regulations.

Hazardous Ingredients

Flame Ionization n-hexane Detector (FID) Sample- 0.33%(w/w) Electron Capture 2,2,4-trimethylpentane Detector Sample Nitrogen/Phosphorus 2,2,4-trimethylpentane Detector Sample Flame Photometric 2,2,4-trimethylpentane Detector Checkout Sample (40)

Supplemental label elements

Flame Ionization Not applicable. elements Detector (FID) Sample- 0.33%(w/w) Electron Capture Not applicable. Detector Sample Nitrogen/Phosphorus Not applicable. Detector Sample Flame Photometric Not applicable. Detector Checkout Sample (40) Headspace OQ/PV

Contains

1,2-dichlorobenzene. May produce an allergic Standard reaction. Annex XVII - Restrictions : Flame Ionization Not applicable. on the manufacture, Detector (FID) Sample- placing on the market 0.33%(w/w) and use of certain Electron Capture Not applicable. dangerous substances, Detector Sample mixtures and articles Nitrogen/Phosphorus Not applicable. Detector Sample Flame Photometric Not applicable. Detector Checkout Sample (40) Headspace OQ/PV Not applicable. Standard

Special packaging requirements

Tactile warning of : Flame Ionization Not applicable. danger Detector (FID) Sample- 0.33%(w/w) Electron Capture Not applicable. Detector Sample Nitrogen/Phosphorus Not applicable. Detector Sample Flame Photometric Not applicable. Detector Checkout Sample (40) Headspace OQ/PV Not applicable. Standard

2.3 Other hazards

Product meets the : Flame Ionization This mixture does not contain any substances that are criteria for PBT or vPvB Detector (FID) Sample- assessed to be a PBT or a vPvB. according to 0.33%(w/w) Regulation (EC) No. Electron Capture This mixture does not contain any substances that are

2.1 Classification of the substance or mixture

0.33%(w/w) Electron Capture None known. Detector Sample Nitrogen/Phosphorus None known. Detector Sample Flame Photometric None known. Detector Checkout Sample (40) Headspace OQ/PV None known. Standard

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.