Note: Ingredients listed on restricted chemical lists
EC/CAS
67-68-5
Name of the chemical
Dimethyl sulfoxide (INN)
Concentration
<10
General Information
Version
6
Revision date
2024-01-19
Product name
Agilent Small RNA Kit, Part Number 5067-1548
1.2.2. Uses advised against
Not for use in diagnostic procedures
Emergency telephone
+(61)-290372994
Icons in SDS
Company Information
company name
Agilent Technologies Australia Pty Ltd
GHS Information
Signal word
Small RNA Gel Matrix No signal word
Hazard Codes
Hazard statements (CLP)
H227, H320
Hazard statements
Code
Statements
H227
Combustible liquid
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
Small RNA Dye Concentrate H227 FLAMMABLE LIQUIDS - Category 4 H320 SERIOUS EYE DAMAGE/EYE IRRITATION - Category 2B Small RNA Gel Matrix Percentage of the mixture consisting of ingredient(s) of unknown hazards to the aquatic environment: 3.6% Small RNA Marker Percentage of the mixture consisting of ingredient(s) of unknown hazards to the aquatic environment: 1% Small RNA Conditioning Percentage of the mixture consisting of ingredient(s) Solution of unknown hazards to the aquatic environment: 3.6%
Signal word
Small RNA Gel Matrix No signal word. Small RNA Marker No signal word. Small RNA Dye Concentrate WARNING Small RNA Conditioning No signal word. Solution Small RNA Ladder No signal word.
Hazard statements
Small RNA Gel Matrix No known significant effects or critical hazards. Small RNA Marker No known significant effects or critical hazards. Small RNA Dye Concentrate H227 - Combustible liquid. H320 - Causes eye irritation. Small RNA Conditioning No known significant effects or critical hazards. Solution Small RNA Ladder No known significant effects or critical hazards.
Prevention
Small RNA Gel Matrix Not applicable. Small RNA Marker Not applicable. Small RNA Dye Concentrate P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Small RNA Conditioning Not applicable. Solution Small RNA Ladder Not applicable.
Response
Small RNA Gel Matrix Not applicable. Small RNA Marker Not applicable. Small RNA Dye Concentrate P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337 + P313 - If eye irritation persists: Get medical advice or attention. Small RNA Conditioning Not applicable. Solution Small RNA Ladder Not applicable.
Storage
Small RNA Gel Matrix Not applicable. Small RNA Marker Not applicable. Small RNA Dye Concentrate Not applicable. Small RNA Conditioning Not applicable. Solution Small RNA Ladder Not applicable.
Disposal
Small RNA Gel Matrix Not applicable. Small RNA Marker Not applicable. Small RNA Dye Concentrate P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations. Small RNA Conditioning Not applicable. Solution Small RNA Ladder Not applicable.
Supplemental label elements
Additional warning : Small RNA Gel Matrix Not applicable. phrases Small RNA Marker Not applicable. Small RNA Dye Concentrate Not applicable. Small RNA Conditioning Not applicable. Solution Small RNA Ladder Not applicable.
Other hazards which do not result in classification
Small RNA Gel Matrix None known. Small RNA Marker None known. Small RNA Dye Concentrate None known. Small RNA Conditioning None known. Solution Small RNA Ladder None known.