Note: Ingredients listed on restricted chemical lists
EC/CAS
202-013-9/90-72-2
Name of the chemical
2,4,6-tris(dimethylaminomethyl)phenol
Concentration
100%
General Information
Revision date
2016-11-08
Product name
2,4,6-tris(dimethylaminomethyl)phenol
CAS No.
90-72-2
1.2.1 Relevant identified uses
Accelerator used in epoxy resins for microscopy
1.2.2. Uses advised against
No further relevant information available
supplier name
Agar Scientific Ltd
Emergency telephone
24 hours +44 (0)1856 407333
Icons in SDS
Company Information
company name
Agar Scientific Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
sales@agarscientific.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H302, H314, H317, H319, H412
Hazard statements
Code
Statements
H302
Harmful if swallowed
Section 2
CLP CLASSIFICATION
GHS05 corrosion Skin Corr. 1B H314 Causes severe skin burns and eye damage. GHS07 Acute Tox. 4 H302 Harmful if swallowed. Eye Irrit. 2 H319 Causes serious eye irritation. Skin Sens. 1B H317 May cause an allergic skin reaction. Aquatic Chronic 3 H412 Harmful to aquatic life with long lasting effects.
EU Classification
Directive 67/548/EEC or Directive 1999/45/EC Xn; Harmful R22: Harmful if swallowed. Xi; Irritant R36/38: Irritating to eyes and skin. · Information concerning particular hazards for human and environment: Not applicable.
2.2 Label elements
Labelling according to Regulation (EC) No 1272/2008 The substance is classified and labelled according to the CLP regulation. (Contd. on page 2) GB (Contd. of page 1)
Hazard pictograms
GHS05 GHS07
Signal word
Danger
Hazard statements
H302 Harmful if swallowed. H314 Causes severe skin burns and eye damage. H317 May cause an allergic skin reaction. H412 Harmful to aquatic life with long lasting effects.
Precautionary statements
P260 Do not breathe dust/fume/gas/mist/vapours/spray. P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P310 Immediately call a POISON CENTER/doctor. P405 Store locked up. P501 Dispose of contents/container in accordance with local/regional/national/ international regulations.
PBT Substances
Not applicable
vPvB Substances
Not applicable