3-D Microemulsion Factory Emulsified

REGENESIS

Revision date : 2011-11-15

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
Health risk rating 1
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

50-21-5

Name of the chemical

lactic acid

Concentration

N/A

EC/CAS

7732-18-5

Name of the chemical

Water, distilled, conductivity or of similar purity H2O

Concentration

N/A

EC/CAS

4075-81-4

Name of the chemical

Propionic acid and its salts

Concentration

N/A

EC/CAS

9000-30-0

Name of the chemical

guar gum

Concentration

N/A

EC/CAS

7757-83-7

Name of the chemical

Sodium sulphite

Concentration

N/A

General Information

Revision date

2011-11-15

Product name

3-D Microemulsion Factory Emulsified

Product Synonyms

HRC Advanced® HRC-PED (Hydrogen Release Compound

Chemical name

oxopropoxyl]-1-oxopropoxy]propanoates]

1.2.1 Relevant identified uses

Used to remediate contaminated groundwater (environmental applications)

supplier name

REGENESIS

Icons in SDS

Company Information

company name

REGENESIS

Section 2

Appearance/Odor

White emulsion. Not detectable Vapor Pressure: None Section 4 — Fire and Explosion Hazard Data Use water spray, carbon dioxide, dry chemical powder or appropriate foam Extinguishing Media: to extinguish fires. Water May be used to keep exposed containers cool. For large quantities involved in a fire, one should wear full protective clothing and a NIOSH approved self contained breathing apparatus with full face piece operated in the pressure demand or positive pressure mode as for a situation where lack of oxygen and excess heat are present.

TOXICOLOGICAL INFORMATION

Acute Effects: May be harmful by inhalation, ingestion, or skin absorption. May cause irritation. Toxicity to Animals LD50 Not available. LC5Q0 Not available Sodium Lactate:

Potential chronic health

on Humans Not Available. Other Toxic Effects on Humans: Very hazardous in case of skin contact (irritant), ingestion and inhalation. Soybean Oil:

Health hazards

Acute and Chronic) Acute: none observed by inhalation. Chronic: none reported. Excessive inhalation of oil mist may affect the respiratory system. Oil mist is Inhalation Risks and classified as a nuisance particulate by ACGIH. Symptoms of Exposure: Regenesis — 3-D Microemulsion® Factory Emulsified MSDS Skin Absorption Health Sensitive individuals may experience dermatitis after long exposure of oil on Risks and Symptoms of skin Exposure: Data Handling: Avoid continued contact with skin. Avoid contact with eyes. In any case of any human exposure which elicits a reaction, a physician should be consulted immediately. First Aid Procedures: Remove to fresh air. If not breathing give artificial respiration. In case of Inhalation: labored breathing give oxygen. Call a physician. No effects expected. Do not give anything to an unconscious person. Call a Ingestion: physician immediately. DO NOT induce vomiting. Eye Contact: Wash eyes with plenty of water for at least 15 minutes lifting both upper and lower lids. Call a physician. Section 7 — Reactivity Data Conditions to Avoid: Strong oxidizing agents, bases and acids Hazardou ‘| Will not occur. Polymerization: Stability: Spontaneous combustion can occur.

Further information

Hydrolyses in water to form lactic acid and soybean oil. Hazardous Decomposition Products: None known. Regenesis — 3-D Microemulsion® Factory Emulsified MSDS Section 8 — Spill, Leak or Accident Procedures Neutralization is not required. The material is very slippery. Spills should be After Spillage or covered with an inert absorbent and then be placed in a container. Wash area Leakage: thoroughly with water. Repeat these steps if slip hazard remains. Laws and regulations for disposal vary widely by locality. Observe all Disposal: applicable regulations and laws. This material may be disposed of in solid waste. Material is readily degradable and hydrolyses in several hours. No requirement for a reportable quantity (CERCLA) of a spill is known. Section 9 — Special Protection or Handling Should be stored in plastic lined steel, plastic, glass, aluminum, stainless steel, or reinforced fiberglass containers. Protective Gloves: Vinyl or Rubber Splash Goggles or Full Face Shield. Area should have approved means of Eyes: ; yes washing eyes. Ventilation: General exhaust. Storage: Store in cool, dry, ventilated area. Protect from incompatible materials. Section 10 — Other Information This material will degrade in the environment by hydrolysis to lactic acid and soybean oil. Materials containing reactive chemicals should be used only by personnel with appropriate chemical training. This material is a non hazardous material in regards to USDOT shipping criteria. The information contained in this document is the best available to the supplier as of the time of writing. Some possible hazards have been determined by analogy to similar classes of material. No separate tests have been performed on the toxicity of this material. The items in this document are subject to change and clarification as more information becomes available. Appendix B-2 BDI PLUS Product Brochure BDI PLUS Product Application Instructions BDI PLUS MSDS BIOAUGMENTATION AND QUANTIFICATION Accelerate the process of complete dechlorination BIOAUGMENTATION TO ACCELERATE THE PROCESS OF COMPLETE DECHLORINATION Bio-Dechlor INOCULUM® is an enriched natural microbial consortium containing YO1HIIG-O18 species of Dehalococcoides sp. (DHC). This microbial consortium has since been enriched to increase its ability to rapidly dechlorinate contaminants during in situ bioremediation processes. Bio-Dechlor INOCULUM has been shown to stimulate the rapid and complete dechlorination of compounds such as tetrachloroethene (PCE), trichloroethene (TCE), dichloroethene (DCE), and vinyl chloride (VC). The most haloethanes (e.g. 1,1,1 TCA and 1,1, DCA) as well as mixtures of these halogenated WNINIONI current culture of Bio Dechlor INOCULUM PLUS(+) now contains microbes capable of dehalogenating halomethanes (e.g. carbon tetrachloride and chloroform) and contaminants. Bio-Dechlor INOCULUM PLUS(+) is provided in a liquid form and Is designed to be injected directly into the contaminated subsurface. Once in place, this microbial consortium works to accelerate the extant rate of chlorinated ethene degradation. When faced with an insufficient quantity of critical dechlorinating microbes, Bio-Dechlor INOCULUM PLUS(+) supplies many beneficial chlorinated solvent degraders including the all important DHC required to achieve complete and rapid dechlorination. SPECIES OF DEHALOCOCCOIDES SP. (DHC) This microbial consortium is compatible with most electron donors however it is often optimized with the addition of any of Regenesis’ Hydrogen Release Compound (HRC®) products. DETECTION AND QUANTIFICATION OF DEHALOCOCCOIDES (DHC) IN THE SUBSURFACE The advent of modern biotechnology has allowed the development of unique and rapid genetic assays for the detection of microorganisms. Bio-Dechlor CENSUS™, an example of this advance, offers a state-of-the-art technique for the quantitative detection of Dehalococcoides, the microbe shown to be required for complete biodegradation of higher chlorinated compounds through to ethene.!:2 Existing analytical technologies offer only a crude qualitative assessment (+/-) of the presence of the required Dehalococcoides species. These tests utilize a common technique known as the Polymerase Chain Reaction (PCR), whereby traces of DNA specific only to microbes of interest (their “fingerprint”) are amplified from environmental samples such that they can be detected. This approach, unfortunately, YOTHIIG-O19 does not allow for specific quantification of the existing and present microbial population, leaving the environmental professional with insufficient information for complete site assessment and management. Regenesis now offers a solution to the quantification SNSNII dilemma, Bio-Dechlor CENSUS. This census of critical microorganisms is a proprietary analysis and is provided by c 2 specialized laboratories in the environmental industry. a . 107 Cells Bio-Dechlor CENSUS utilizes a process termed “Real-Time E 40° 10° Cells MMM PCR” in which the DNA amplification step is actually g 10° Cells quantified with a fluorescent signal, indicating the number gs ; of target microbes in the sample (Figure 1). This valuable 5 <* quantitative information allows environmental professionals © SISINIDIY to properly assess project sites for the potential for natural @ 10" WOO biodegradation of chlorinated contaminants and the degree 5 of bioaugmentation that may be required. a aa 246 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 —_ or Cycle 1. Maymo-Gatell, X.; Y-T Chien; J.M Gossett; S.H. Zinder, Science 1997, 276, 1568-1571. 2. Léffler, F.E.; Q. Sun; J. Li; J.M. Tiedje; Applied Environmental Microbiology 2000, 66(4), FIGURE 1: REAL-TIME PCR AMPLIFICATION OF 10-FOLD DILUTIONS 1369-1374. OF GENOMIC DNA DERIVED FROM DEHALOCOCCOIDES Bio-Dechlor g INOCULUM REGENESIS PLUS” Advanced Technologies for Groundwater Resources Bio-Dechlor INOCULUM PLUS (BDI PLUS™) Application Instructions (Direct-Push Injection) General Information Bio-Dechlor INOCUL UM PLUS (BDI PL US™) is an enriched natural microbial consortium containing species of Dehalococcoides. This microbial consortium has since been enriched to increase its ability to rapidly dechlorinate contaminants during in situ bioremediation processes. BDI PLUS has been shown to stimulate the rapid and complete dechlorination of compounds such as tetrachloroethene (PCE), trichloroethene (TCE), dichloroethene (DCE), and vinyl chloride (VC). BDI PLUS also contains microorganisms capable of degrading chloromethanes (carbon tetrachloride and chloroform) as well as chloroethanes like trichloroethane (TCA). Recent trends in engineered bioremediation indicate that the treatment of chlorinated solvent contamination sometimes results in slow or incomplete degradation of the intermediate compounds. When faced with this circumstance, bioaugmentation with a microbial consortium such as BDI PLUS offers a solution to accelerate or simply make possible the complete dechlorination of these otherwise recalcitrant compounds. Regenesis believes that the best approach to install BDI PLUS into the subsurface is by direct-push methods. This allows for the BDI PLUS solution to be applied directly into the aquifer material and provides greater coverage/treatment over the life of the project. As a minimum, the following equipment will be needed to perform this type of installation: o Direct-push drilling unit o Grout pump (e.g. Geoprobe GS 2000) o Appropriate hose assembly including a fitting that links a hose from the grout pump to the direct-push rods (provided by Regenesis with shipment) o One or more 55+ gallon water drums, fitted with an appropriate lid that has at least one bung hole (number of drums depends on size of application) o Rotary transfer pump (or equivalent) with appropriate amount of hose to connect from 55-gal drum to hopper of grout pump (similar to Grainger No. 1P893, Fill- Rite model

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.