Note: Ingredients listed on restricted chemical lists
EC/CAS
9016-87-9
Name of the chemical
4,4'-Methylendiphenyldiisocyanat tech. (Polymeres) MDI, pMDI (in Form atembarer Aerosole, A-Fraktion)
Concentration
40-60
EC/CAS
28553-12-0
Name of the chemical
Di-isononyl phthalate(DINP),5
Concentration
10-30
EC/CAS
1333-86-4
Name of the chemical
carbon black
Concentration
0.1-1
General Information
Revision date
2016-06-07
Product name
FLAMMABLE LIQUID, N.O.S. (contains xylene)
1.2.1 Relevant identified uses
Moisture cured water proofing membrane
Emergency telephone
+61 2 8021 3517 (Mon-Fri 8am to 5pm; Sat 8.30am to 12.30pm
Icons in SDS
Company Information
company name
Actech Protective Coatings
e-mail address of the competent person responsible for the Safety Data Sheet
Actech.pc@optusnet.com.au
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H226, H312, H315, H317, H318, H332, H334, H335, H351, H373, H402
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
2.1 Classification of the substance or mixture
HAZARDOUS CHEMICAL. DANGEROUS GOODS. According to the WHS Regulations and the ADG Code. CHEMWATCH HAZARD RATINGS Min Max Flammability 2 Toxicity 2 0 = Minimum Body Contact 3 1 = Low 2 = Moderate Reactivity 1 3 = High Chronic 2 4 = Extreme Poisons Schedule S6 Flammable Liquid Category 3, Acute Toxicity (Dermal) Category 4, Acute Toxicity (Inhalation) Category 4, Skin Corrosion/Irritation Category 2, Serious Eye [1] Damage Category 1, Respiratory Sensitizer Category 1, Skin Sensitizer Category 1, Carcinogenicity Category 2, Specific target organ toxicity - single exposure Category 3 (respiratory tract irritation), Specific target organ toxicity - repeated exposure Category 2, Acute Aquatic Hazard Category 3 Legend: 1. Classified by Chemwatch; 2. Classification drawn from HSIS ; 3. Classification drawn from EC Directive 1272/2008 - Annex VI
Signal word
DANGER
Hazard statements
H226 Flammable liquid and vapour. H312 Harmful in contact with skin. H332 Harmful if inhaled. H315 Causes skin irritation. H318 Causes serious eye damage. H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. H317 May cause an allergic skin reaction. H351 Suspected of causing cancer. H335 May cause respiratory irritation. H373 May cause damage to organs. H402 Harmful to aquatic life
Prevention
P201 Obtain special instructions before use. P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking. P260 Do not breathe dust/fume/gas/mist/vapours/spray. P271 Use only outdoors or in a well-ventilated area. P280 Wear protective gloves/protective clothing/eye protection/face protection. P281 Use personal protective equipment as required. P285 In case of inadequate ventilation wear respiratory protection. P240 Ground/bond container and receiving equipment. P241 Use explosion-proof electrical/ventilating/lighting/intrinsically safe equipment. P242 Use only non-sparking tools. P243 Take precautionary measures against static discharge. P273 Avoid release to the environment. P272 Contaminated work clothing should not be allowed out of the workplace.
Response
P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P308+P313 IF exposed or concerned: Get medical advice/attention. P310 Immediately call a POISON CENTER or doctor/physician. P342+P311 If experiencing respiratory symptoms: Call a POISON CENTER or doctor/physician. P362 Take off contaminated clothing and wash before reuse. P363 Wash contaminated clothing before reuse. P370+P378 In case of fire: Use alcohol resistant foam or normal protein foam for extinction. P302+P352 IF ON SKIN: Wash with plenty of soap and water. P333+P313 If skin irritation or rash occurs: Get medical advice/attention. P303+P361+P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.
Storage
P403+P235 Store in a well-ventilated place. Keep cool. P405 Store locked up. P403+P233 Store in a well-ventilated place. Keep container tightly closed.
Disposal
P501 Dispose of contents/container in accordance with local regulations.