Note: Ingredients listed on restricted chemical lists
EC/CAS
64741-65-7
Name of the chemical
Petroleum, coal, tar and natural gas and their derivatives generated using distillation and/or other processing methods if they contain ≥ 0,1 % w/w benzene
Concentration
22.5%
General Information
Version
1,00
Revision date
2015-04-23
Product name
ACMOSIL 34-4034
supplier name
ACMOS Inc
Manufacturer Name
ACMOS CHEMIE KG
Emergency telephone
+49 (0)421-5189-0, +49 (0)421-511415, +49 (0)551-19240, 001-410-296-5994, 001-410-296-5998, 001-410-736-9922, 1-800-424-9300
Icons in SDS
Company Information
company name
ACMOS CHEMIE KG
e-mail address of the competent person responsible for the Safety Data Sheet
acmos@acmos.com, acmosinc@acmosinc.com, reinhard@acmosinc.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H227, H304
Hazard statements
Code
Statements
H227
Combustible liquid
Section 2
SECTION 2: Hazards identification
1999/45/EC Classification of the chemical This mixture is classified as not hazardous according to 1999/45/EC
Hazard categories
Flammable liquid: Flam. Liq. 4 Aspiration hazard: Asp. Tox. 1 Hazard Statements Combustible liquid May be fatal if swallowed and enters airways
Signal word
Danger
Hazard statements
Combustible liquid May be fatal if swallowed and enters airways
Precautionary statements
Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Wear protective gloves/protective clothing/eye protection/face protection. If swallowed: Immediately call a poison center/doctor. Do NOT induce vomiting. In case of fire: Use Water mist/Extinguishing powder/Foam/Carbon dioxide (CO2) to extinguish.
Supplemental label elements
Labelling according to the revised Hazard Communication Standard (HCS 2012) according to 29 CFR 1910.1200(f)
Other physicochemical hazards
See section 9 for physical and chemical properties. This material is combustible, but will not ignite readily. The vapour of the product is heavier than air and may accumulate below ground level, in pits, channels and basements in higher concentration. Vapours of flammable solvents can accumulate in the gas phase of closed container, especially during heat treatment. Therefore keep away from fire and sources of ignition. This material can accumulate static charge by flow or agitation and can be ignited by static discharge. The product will be applied by spraying. In use, may form flammable/explosive vapour-air mixture.
Potential health effects
See section 11 for toxicological information. Inhalation of aerosol mists can cause damage to health.
Environmental effects
See section 12 for environmental information.
Other hazards
Special danger of slipping by leaking/spilling product.
Results of PBT and vPvB assessment
See under section 12.5 - Results of PBT and vPvB assessment.
2.1 Classification of the substance or mixture
This mixture is classified as not hazardous according to 1999/45/EC. Hazard categories: Flammable liquid: Flam. Liq. 4 Aspiration hazard: Asp. Tox. 1 Hazard Statements: Combustible liquid May be fatal if swallowed and enters airways