Note: Ingredients listed on restricted chemical lists
EC/CAS
108-88-3
Name of the chemical
Toluene
Concentration
N/A
EC/CAS
110-54-3
Name of the chemical
n-Hexan (790/2009)
Concentration
N/A
EC/CAS
71-43-2
Name of the chemical
Benzol
Concentration
N/A
EC/CAS
110-82-7
Name of the chemical
Cyclohexane
Concentration
N/A
EC/CAS
86290-81-5
Name of the chemical
Gasoline
Concentration
N/A
EC/CAS
289-220-8
Name of the chemical
Gasoline
Concentration
N/A
General Information
Revision date
2012-09-28
Product name
Gravimetric Standard 512
Icons in SDS
Company Information
company name
AC Analytical Controls BV
e-mail address of the competent person responsible for the Safety Data Sheet
safety.netherlands@paclp.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H224, H304, H315, H336, H340, H350, H361d, H411
Hazard statements
Code
Statements
H224
Extremely flammable liquid and vapour
Section 2
2.1 Classification of the substance or mixture
Regulation (EC) No 1272/2008
Hazard categories
Flammable Liquids (Category 1) Skin corrosion/irritation (Category 2)
Aspiration hazard
Category 1) Reproductive toxicity (Category 2) Germ cell mutagenicity (Category 1B) STOT-SE (Category 3) Aqua Chronic (Category 2)
2.2 Label elements
Labeling according to Regulation (EC) No 1272/2008
Signal word
Danger
Physical hazards
H224 Extremely flammable liquid and vapor
Health hazards
H315 Causes skin irritation. H304 May be fatal if swallowed and enters airways. H361d Suspected of damaging the unborn child. H350 May cause cancer. H340 May cause genetic defects. H336 May cause drowsiness or dizziness. Slightly irritating to respiratory system Safety Hazards Electrostatic charges may be generated during handling. Electrostatic discharge may cause fire. Liquid evaporates quickly and can ignite leading to a flash fire, or an explosion in a confined space.
Environmental hazards
H411 Toxic to aquatic life with long lasting effects.
Prevention
P201; P210; P280
Response
P301+P310
Storage
P403+P233
Disposal
P501
Further information
This product is intended for use in closed systems only.