Note: Ingredients listed on restricted chemical lists
EC/CAS
75-28-5
Name of the chemical
iso-Butan, enthält 0,1% Butadien
Concentration
>99
General Information
Version
6.1
Revision date
2022-06-20
Product name
R6OOA (ISOBUTANE)
Product name
R6OOA (ISOBUTANE)
Identification on the label/Trade name
ISOBUTANE
Product Synonyms
trimethylmethane; i-butane; R600a; Care 10; CARE 10 Refrigerant Fluid R600a
CAS No.
75-28-5
1.2.1 Relevant identified uses
The use of a quantity of material in an unventilated or confined space may result in increased exposure and an irritating atmosphere developing. Before starting consider control of exposure by mechanical ventilation
Emergency telephone
+44 (0) 1275 376600, +44 20 3901 3542, +44 808 164 9592
Icons in SDS
Company Information
company name
A-Gas (UK) Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
info.uk@agas.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H220, H280
Hazard statements
Code
Statements
H220
Extremely flammable gas
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
Classified according to GB-CLP Regulation, UK SI 2019/720 and UK SI 2020/1567 !41 H220 - Flammable gases, Hazard Category 1A, H280 - Gases Under Pressure (Liquefied Gas) Legend 1. Classified by Chemwatch,; 2. Classification drawn from GB-CLP Regulation, UK SI 2019/720 and UK SI 2020/1567
2.2 Label elements
Page 1 continued... Chemwaitch: 1969-1 Page 2 of 13 Issue Date: 20/06/2022
Signal word
Danger
Hazard statements
H220 Extremely flammable gas. H280 Contains gas under pressure; may explode if heated.
Supplemental label elements
EUH044 Risk of explosion if heated under confinement.
Precautionary statements
P101 If medical advice is needed, have product container or label at hand. P102 Keep out of reach of children. P103 Read carefully and follow all instructions.
Prevention
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
Response
P377 Leaking gas fire: Do not extinguish, unless leak can be stopped safely. P381 In case of leakage, eliminate all ignition sources.
Storage
P410+P403 Protect from sunlight. Store in a well-ventilated place.
Disposal
Not Applicable Material does not contain any CLP Article 18 substances.
2.3 Other hazards
iso-butane Listed in the Europe Regulation