Note: Ingredients listed on restricted chemical lists
EC/CAS
124-38-9
Name of the chemical
Carbon dioxide CO2
Concentration
>60
General Information
Version
3.1.1.1
Revision date
2019-11-01
Product name
A-Gas R744
Product name
A-Gas R744
Identification on the label/Trade name
CARBON DIOXIDE, REFRIGERATED LIQUID
Product Synonyms
Not Available
1.2.1 Relevant identified uses
Carbonating/ pressure dispensing Fire fighting Food packaging Freezing applications Welding
Emergency telephone
+61 1800 024 973
Icons in SDS
Company Information
company name
A-Gas (A-Gas (Australia))
GHS Information
Signal word
WARNING
Hazard Codes
Hazard statements (CLP)
H280, H413
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
Section 2
SECTION 2: Hazards identification
No 1272/2008 Classification of the substance or mixture
Signal word
WARNING
Hazard statements
H280 Contains gas under pressure; may explode if heated. H413 May cause long lasting harmful effects to aquatic life. AUHO044 Risk of explosion if heated under confinement.
Supplemental label elements
Not Applicable
Precautionary statements
P101 If medical advice is needed, have product container or label at hand. P102 Keep out of reach of children. P103 Read label before use.
Prevention
P273 Avoid release to the environment.
Response
Not Applicable
Storage
P410+P403 | Protect from sunlight. Store in a well-ventilated place.
Disposal
pP501 | Dispose of contents/container to authorised hazardous or special waste collection point in accordance with any local regulation.
2.1 Classification of the substance or mixture
| HAZARDOUS CHEMICAL. DANGEROUS GOODS. According to the WHS Regulations and the ADG Code. CHEMWATCH HAZARD RATINGS Min Max Flammability 0 Toxicity 1 0 = Minimum Body Contact 0 ; - Neerate Reactivity 1 3 = High Chronic 0 4= Extreme Poisons Schedule Not Applicable Classification [4] Gas under Pressure (Liquefied gas), Chronic Aquatic Hazard Category 4 Legend: 1. Classified by Chemwatch; 2. Classification drawn from HCIS; 3. Classification drawn from Regulation (EU) No 1272/2008 - Annex VI