GHS07 GHS08
Health risk rating 5
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

822-06-0

Name of the chemical

Hexamethylene diisocyanate

Concentration

<0.25

General Information

Version

1.04

Revision date

2018-07-24

Product name

3M Scotchkote Urethane Wall Coating UV 843 (Part B)

1.2.1 Relevant identified uses

Coating., UV wall coating

supplier name

3M Technologies (S) Pte Ltd

Emergency telephone

+65 6591 6888

Icons in SDS

GHS07 GHS08

Company Information

company name

3M Technologies (S) Pte Ltd

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H317, H334, H335

Hazard statements

Code

Statements

H317

May cause an allergic skin reaction

Section 2

SECTION 2: Hazards identification

Classification of the substance or mixture Respiratory Sensitizer: Category 1A Skin Sensitizer: Category 1A Specific Target Organ Toxicity (single exposure): Category 3

Hazard pictograms

Exclamation mark | Health Hazard |

Hazard statements

H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. H317 May cause an allergic skin reaction. H335 May cause respiratory irritation.

Prevention

P261 Avoid breathing dust/fume/gas/mist/vapours/spray. P271 Use only outdoors or in a well-ventilated area. P284 Wear respiratory protection. P280E Wear protective gloves.

Response

P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. P342 + P311 If experiencing respiratory symptoms: Call a POISON CENTER or doctor/physician. P333 + P313 If skin irritation or rash occurs: Get medical advice/attention.

Storage

P405 Store locked up.

Disposal

P501 Dispose of contents/container in accordance with applicable local/regional/national/international regulations.

2.3 Other hazards

Persons previously sensitised to isocyanates may develop a cross-sensitisation reaction to other isocyanates.

2.1 Classification of the substance or mixture

Respiratory Sensitizer: Category 1A. Skin Sensitizer: Category 1A. Specific Target Organ Toxicity (single exposure): Category 3.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.