Note: Ingredients listed on restricted chemical lists
EC/CAS
101-68-8
Name of the chemical
4,4’-Methylenediphenyl diisocyanate
Concentration
30-60
EC/CAS
1333-86-4
Name of the chemical
Carbon black
Concentration
0.1-1
General Information
Revision date
2013-05-16
Product name
3M Duramix Plastic Repair, Semi-Rigid PNs 4040, 04240 Base (Part A)
supplier name
3M New Zealand Ltd
Emergency telephone
24 hr Medical Emergency, National Poisons Centre, 0800 764 766 (0800 POISON
Icons in SDS
Company Information
company name
3M New Zealand Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
innovation@nz.mmm.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H315, H317, H319, H334, H335, H351, H372
Hazard statements
Code
Statements
H315
Causes skin irritation
H317
May cause an allergic skin reaction
H319
Causes serious eye irritation
H334
May cause allergy or asthma symptoms or breathing difficulties if inhaled
H335
May cause respiratory irritation
H351
Suspected of causing cancer
H372
Causes damage to organs through prolonged or repeated exposure
Section 2
2.1 Classification of the substance or mixture
Classified as hazardous according to the New Zealand Hazardous Substances (Minimum Degrees of Hazard) Regulations 2001. Not classified as a Dangerous Good according to; NZS 5433:2012 Transport of Dangerous Goods on Land, UN, IMDG and IATA.
HSNO Classifications
6.1E Acute toxicity 6.3A Irritating to the skin 6.4A Irritating to the eye 6.5A Respiratory sensitiser 6.5B Skin sensitiser 6.7B Suspected human carcinogen 6.9A Toxic to human target organs/systems
Health hazards
Exclamation mark
Hazard statements
H335 May cause respiratory irritation. H319 Causes serious eye irritation. H315 Causes skin irritation. H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. H317 May cause an allergic skin reaction. H351 Suspected of causing cancer. H372 Causes damage to organs through prolonged or repeated exposure: respiratory system |
Precautionary statements
General: P101 If medical advice is needed, have product container or label at hand. P102 Keep out of reach of children. P103 Read label before use.
Prevention
P104 Read Safety Data Sheet before use. P201 Obtain special instructions before use. P202 Do not handle until all safety precautions have been read and understood. P260 Do not breathe dust/fume/gas/mist/vapours/spray. P261 Avoid breathing dust/fume/gas/mist/vapours/spray. P271 Use only outdoors or in a well-ventilated area. P285 In case of inadequate ventilation wear respiratory protection. P280A Wear eye/face protection. P280E Wear protective gloves. P281 Use personal protective equipment as required. P270 Do not eat, drink or smoke when using this product. P264 Wash thoroughly after handling. P272 Contaminated work clothing should not be allowed out of the workplace.
Response
P304 + P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. P304 + P341 IF INHALED: If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. P342 + P311 If experiencing respiratory symptoms: Call a POISON CENTER or doctor/physician. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337 + P313 If eye irritation persists: Get medical advice/attention. P302 + P352 IF ON SKIN: Wash with plenty of soap and water. P332 + P313 If skin irritation occurs: Get medical advice/attention. P333 + P313 If skin irritation or rash occurs: Get medical advice/attention. P362 + P364 Take off contaminated clothing and wash before reuse. P363 Wash contaminated clothing before reuse. P308 + P313 IF exposed or concerned: Get medical advice/attention. P321 Specific treatment (see Notes to Physician on this label). P312 Call a POISON CENTRE or doctor/physician if you feel unwell. P314 Get medical advice/attention if you feel unwell.
Storage
P403 + P233 Store in a well-ventilated place. Keep container tightly closed. P405 Store locked up.
Disposal
P501 Dispose of contents/container in accordance with applicable local/regional/national/international regulations.
2.3 Other hazards
Persons previously sensitised to isocyanates may develop a cross-sensitisation reaction to other isocyanates.