Note: Ingredients listed on restricted chemical lists
EC/CAS
7732-18-5
Name of the chemical
Water, distilled, conductivity or of similar purity H2O
Concentration
N/A
General Information
Revision date
2013-01-03
Product name
3M(TM) Finesse-it(TM) II Finishing Material, 05928, 05929, 05932
CAS No.
7732-18-5
Manufacturer Name
3M(TM) Finesse-it(TM) II Finishing Material
Emergency telephone
1-800-364-3577 or (651) 737-6501 (24 hours
Icons in SDS
Company Information
company name
3m company
Section 2
SECTION 2: Hazards identification
3.1 EMERGENCY OVERVIEW Specific Physical Form: Emulsion Odor, Color, Grade: Slight solvent odor, white liquid General Physical Form: Liquid Immediate health, physical, and environmental hazards: Combustible liquid and vapor. Closed containers exposed to heat from fire may build pressure and explode. Vapors may travel long distances along the ground or floor to an ignition source and flash back. May cause target organ effects.
Potential health effects
Eye Contact: Mild Eye Irritation: Signs/symptoms may include redness, pain, and tearing. Skin Contact: Mild Skin Irritation: Signs/symptoms may include localized redness, swelling, and itching. Inhalation: Respiratory Tract Irritation: Signs/symptoms may include cough, sneezing, nasal discharge, headache, hoarseness, and nose and throat pain. May be absorbed following inhalation and cause target organ effects. Ingestion: Gastrointestinal Irritation: Signs/symptoms may include abdominal pain, stomach upset, nausea, vomiting and diarrhea. May be absorbed following ingestion and cause target organ effects. Target Organ Effects: Central Nervous System (CNS) Depression: Signs/symptoms may include headache, dizziness, drowsiness, incoordination, nausea, slowed reaction time, slurred speech, giddiness, and unconsciousness. SECTION 4: FIRST AID MEASURES 4.1 FIRST AID PROCEDURES The following first aid recommendations are based on an assumption that appropriate personal and industrial hygiene practices are followed. Eye Contact: Flush eyes with large amounts of water. If signs/symptoms persist, get medical attention. Skin Contact: Wash affected area with soap and water. If signs/symptoms develop, get medical attention. Inhalation: Remove person to fresh air. If signs/symptoms develop, get medical attention. If Swallowed: Do not induce vomiting unless instructed to do so by medical personnel. Give victim two glasses of water. Never give anything by mouth to an unconscious person. Get medical attention. SECTION 5: FIRE FIGHTING MEASURES 5.1 FLAMMABLE PROPERTIES Autoignition temperature No Data Available Flash Point 186 ºF [Test Method: Closed Cup] Flammable Limits(LEL) No Data Available Flammable Limits(UEL) No Data Available 5.2 EXTINGUISHING MEDIA Use fire extinguishers with class B extinguishing agents (e.g., dry chemical, carbon dioxide). 5.3 PROTECTION OF FIRE FIGHTERS Special Fire Fighting Procedures: Water may not effectively extinguish fire; however, it should be used to keep fire-exposed containers and surfaces cool and prevent explosive rupture. Wear full protective equipment (Bunker Gear) and a self-contained breathing apparatus (SCBA). Unusual Fire and Explosion Hazards: Combustible liquid and vapor. Closed containers exposed to heat from fire may build pressure and explode. Vapors may travel long distances along the ground or floor to an ignition source and flash back. Note: See STABILITY AND REACTIVITY (SECTION 10) for hazardous combustion and thermal decomposition information. SECTION 6: ACCIDENTAL RELEASE MEASURES 6.1. Personal precautions, protective equipment and emergency procedures Evacuate unprotected and untrained personnel from hazard area. The spill should be cleaned up by qualified personnel. Remove all ignition sources such as flames, smoking materials, and electrical spark sources. Use only non-sparking tools. Ventilate the area with fresh air. For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors, in accordance with good industrial hygiene practice. Warning! A motor could be an ignition source and could cause flammable gases or vapors in the spill area to burn or explode. 6.2. Environmental precautions For larger spills, cover drains and build dikes to prevent entry into sewer systems or bodies of water. Place in a closed container approved for transportation by appropriate authorities. Dispose of collected material as soon as possible. Clean-up methods Observe precautions from other sections. Call 3M- HELPS line (1-800-364-3577) for more information on handling and managing the spill. Contain spill. Working from around the edges of the spill inward, cover with bentonite, vermiculite, or commercially available inorganic absorbent material. Mix in sufficient absorbent until it appears dry. Collect as much of the spilled material as possible using non-sparking tools. Clean up residue with an appropriate solvent selected by a qualified and authorized person. Ventilate the area with fresh air. Read and follow safety precautions on the solvent label and MSDS. In the event of a release of this material, the user should determine if the release qualifies as reportable according to local, state, and federal regulations. SECTION 7: HANDLING AND STORAGE 7.1 HANDLING Do not eat, drink or smoke when using this product. Wash exposed areas thoroughly with soap and water. Keep away from heat, sparks, open flame, pilot lights and other sources of ignition. Avoid breathing of vapors, mists or spray. Keep out of the reach of children. Avoid contact with oxidizing agents. Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below Occupational Exposure Limits. If ventilation is not adequate, use respiratory protection equipment. Avoid eye contact. Avoid prolonged or repeated skin contact.
Storage
Store away from acids. Store away from heat. Store out of direct sunlight. Store away from areas where product may come into contact with food or pharmaceuticals. Store away from oxidizing agents. SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION 8.1 ENGINEERING CONTROLS Use in an enclosed process area is recommended. Do not use in a confined area or areas with little or no air movement. Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below Occupational Exposure Limits and/or control mist, vapor, or spray. If ventilation is not adequate, use respiratory protection equipment. 8.2 PERSONAL PROTECTIVE EQUIPMENT (PPE) 8.2.1 Eye/Face Protection Avoid eye contact. The following eye protection(s) are recommended: Safety Glasses with side shields Indirect Vented Goggles . 8.2.2 Skin Protection Avoid prolonged or repeated skin contact. Select and use gloves and/or protective clothing to prevent skin contact based on the results of an exposure assessment. Consult with your glove and/or protective clothing manufacturer for selection of appropriate compatible materials. Gloves made from the following material(s) are recommended: Neoprene . 8.2.3 Respiratory Protection Avoid breathing of vapors, mists or spray. An exposure assessment may be needed to decide if a respirator is required. If a respirator is needed, use respirators as part of a full respiratory protection program. Based on the results of the exposure assessment, select from the following respirator type(s) to reduce inhalation exposure: Half facepiece or full facepiece air-purifying respirator suitable for organic vapors and particulates Half facepiece or full facepiece air-purifying respirator suitable for particulates For questions about suitability for a specific application, consult with your respirator manufacturer. 8.2.4 Prevention of Swallowing Do not eat, drink or smoke when using this product. Wash exposed areas thoroughly with soap and water. 8.3 EXPOSURE GUIDELINES Ingredient Authority Type Limit Additional Information ALUMINUM OXIDE CMRG TWA 1 fiber/cc ALUMINUM OXIDE OSHA TWA, respirable 5 mg/m3 fraction ALUMINUM OXIDE OSHA TWA, as total dust 15 mg/m3 ALUMINUM OXIDE (FIBROUS FORMS OSHA TWA, respirable 5 mg/m3 ONLY) fraction ALUMINUM OXIDE (FIBROUS FORMS OSHA TWA, as total dust 15 mg/m3 ONLY) Aluminum, insoluble compounds ACGIH TWA, respirable 1 mg/m3 fraction DECAMETHYLCYCLOPENTASILOXANE CMRG TWA 10 ppm GLYCERIN ACGIH TWA, as mist 10 mg/m3 GLYCERIN OSHA TWA, respirable 5 mg/m3 fraction GLYCERIN OSHA TWA, as total dust 15 mg/m3 HYDROTREATED HEAVY NAPHTHA Manufacturer TWA 100 ppm (PETROLEUM) determined HYDROTREATED LIGHT PETROLEUM CMRG TWA 165 ppm DISTILLATES Kerosine (petroleum) ACGIH TWA, as total 200 mg/m3 Skin Notation* hydrocarbon vapor, non-aerosol MINERAL OILS, HIGHLY-REFINED OILS ACGIH TWA, inhalable 5 mg/m3 fraction Paraffin oil OSHA TWA, as mist 5 mg/m3 SILICA, AMORPHOUS OSHA TWA concentration 0.8 mg/m3 SILICA, AMORPHOUS OSHA TWA 20 millions of particles/cu. ft. SOURCE OF EXPOSURE LIMIT DATA: ACGIH: American Conference of Governmental Industrial Hygienists CMRG: Chemical Manufacturer Recommended Guideline OSHA: Occupational Safety and Health Administration AIHA: American Industrial Hygiene Association Workplace Environmental Exposure Level (WEEL) SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES Specific Physical Form: Emulsion Odor, Color, Grade: Slight solvent odor, white liquid General Physical Form: Liquid Autoignition temperature No Data Available Flash Point 186 ºF [Test Method: Closed Cup] Flammable Limits(LEL) No Data Available Flammable Limits(UEL) No Data Available Boiling Point > 95 ºF [@ 760 mmHg] [Details: (Test Method ASTM D1120-94)] Density 1.03 g/ml Vapor Density No Data Available Vapor Pressure 6.3 mmHg [@ 20 ºC] [Details: (Test Method ASTM E-1719-97)] Specific Gravity 1.03 [Ref Std: WATER=1] pH 7.5 - 8.5 Melting point No Data Available Solubility in Water Negligible Evaporation rate No Data Available Hazardous Air Pollutants 0.0062 % weight [Test Method: Calculated] Volatile Organic Compounds 145 g/l [Test Method: calculated SCAQMD rule 443.1] Volatile Organic Compounds 14.0 % weight [Test Method: calculated per CARB title 2] Kow - Oct/Water partition coef No Data Available Percent volatile 79.1 % VOC Less H2O & Exempt Solvents 439 g/l [Test Method: calculated SCAQMD rule 443.1] Viscosity 12000 - 16000 SECTION 10: STABILITY AND REACTIVITY Stability: Stable. Materials and Conditions to Avoid: 10.1 Conditions to avoid Heat Sparks and/or flames 10.2 Materials to avoid Strong acids Strong oxidizing agents Hazardous Polymerization: Hazardous polymerization will not occur. Hazardous Decomposition or By-Products