3M Power Tools with Air Tool Lubricant, Back-up Pads; Elite's

3M

Revision date : 2015-10-13

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
Health risk rating
Safety risk rating
Environmental risk rating

Note: Ingredients listed on restricted chemical lists

EC/CAS

64742-54-7

Name of the chemical

Distillates (petroleum), hydrotreated heavy paraffinic

Concentration

85-95 5-10

EC/CAS

63449-39-8

Name of the chemical

Paraffin waxes, chloro

Concentration

2-3

EC/CAS

64742-53-6

Name of the chemical

Distillates (petroleum), hydrotreated light naphthenic

Concentration

0.5-0.8

EC/CAS

64742-65-0

Name of the chemical

Distillates (petroleum), solvent-dewaxed heavy paraffinic

Concentration

0.1-0.4

General Information

Version

1.00

Revision date

2015-10-13

Product name

3M Power Tools with Air Tool Lubricant, Back-up Pads; Elite's

1.2.1 Relevant identified uses

Lubricating Oil for Tools

Icons in SDS

Company Information

company name

3M

e-mail address of the competent person responsible for the Safety Data Sheet

falecoma3M@mmm.com

GHS Information

Signal word

Not applicable

Section 2

SECTION 2: Hazards identification

Classification of the substance or mixture Product is not classified as hazardous according to ABNT NBR 14725-2

Signal word

Not applicable.

Hazard pictograms

Not applicable. Not applicable. 99% of the mixture consists of ingredients of unknown hazards to the aquatic environment.

2.1 Classification of the substance or mixture

Product is not classified as hazardous according to ABNT NBR 14725-2 2.2. Label elements SIGNAL WORD Not applicable. Symbols Not applicable. Pictograms Not applicable. 99% of the mixture consists of ingredients of unknown hazards to the aquatic environment. SECTION 3: Composition/information on ingredients This material is a mixture. Ingredient C.A.S. No. % by Wt Lubricating Oils Mixture 85 - 95 Hydrotreated Heavy Paraffinic Distillate 64742-54-7 5 - 10 Lubricant 63449-39-8 2 - 3 Hydrotreated light naphthenic petroleum 64742-53-6 0.5 - 0.8 distillates Petroleum Distillates 64742-65-0 0.1 - 0.4 SECTION 4: First aid measures 4.1. Description of first aid measures Inhalation: No need for first aid is anticipated. Skin Contact: No need for first aid is anticipated. Eye Contact: Flush with large amounts of water. Remove contact lenses if easy to do. Continue rinsing. If signs/symptoms persist, get medical attention. If Swallowed: Rinse mouth. If you feel unwell, get medical attention. 4.2. Most important symptoms and effects, both acute and delayed See Section 11.1. Information on toxicological effects. 4.3. Indication of any immediate medical attention and special treatment required Not applicable SECTION 5: Fire-fighting measures 5.1. Suitable extinguishing media In case of fire: Use a carbon dioxide or dry chemical extinguisher to extinguish. 5.2. Special hazards arising from the substance or mixture None inherent in this product. Hazardous Decomposition or By-Products Substance Condition Carbon monoxide During Combustion Carbon dioxide During Combustion 5.3. Special protective actions for fire-fighters No special protective actions for fire-fighters are anticipated. SECTION 6: Accidental release measures 6.1. Personal precautions, protective equipment and emergency procedures Evacuate area. Ventilate the area with fresh air. For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors, in accordance with good industrial hygiene practice. 6.2. Environmental precautions Avoid release to the environment. 6.3. Methods and material for containment and cleaning up Contain spill. Working from around the edges of the spill inward, cover with bentonite, vermiculite, or commercially available inorganic absorbent material. Mix in sufficient absorbent until it appears dry. Remember, adding an absorbent material does not remove a physical, health, or environmental hazard. Collect as much of the spilled material as possible. Place in a closed container approved for transportation by appropriate authorities. Clean up residue with an appropriate solvent selected by a qualified and authorized person. Ventilate the area with fresh air. Read and follow safety precautions on the solvent label and SDS. Seal the container. Dispose of collected material as soon as possible. SECTION 7: Handling and storage 7.1. Precautions for safe handling Do not eat, drink or smoke when using this product. Wash thoroughly after handling. Avoid contact with oxidizing agents (eg. chlorine, chromic acid etc.) 7.2. Conditions for safe storage including any incompatibilities Store away from heat. Store away from acids. Store away from oxidizing agents. SECTION 8: Exposure controls/personal protection 8.1. Control parameters Occupational exposure limits If a component is disclosed in section 3 but does not appear in the table below, an occupational exposure limit is not available for the component. Ingredient C.A.S. No. Agency Limit type Additional Comments Hydrotreated light naphthenic 64742-53-6 CMRG TWA:5 mg/m3 petroleum distillates PETROLEUM DISTILLATES 64742-53-6 OSHA TWA:2000 mg/m3(500 ppm) Mineral oils (untreated and mildly 64742-53-6 ACGIH Limit value not established: A2: Suspected human treated) carcin., Cntrl all exposr- low as possib Paraffin oil 64742-53-6 OSHA TWA(as mist):5 mg/m3 Mineral oils (untreated and mildly 64742-54-7 ACGIH Limit value not established: A2: Suspected human treated) carcin., Cntrl all exposr- low as possib MINERAL OILS, HIGHLY- 64742-54-7 ACGIH TWA(inhalable fraction):5 A4: Not class. as human REFINED OILS mg/m3 carcin MINERAL OILS, HIGHLY- 64742-54-7 Brazil OELs TWA(inhalable fraction)(8 REFINED OILS hours):5 mg/m3 Mineral oils (untreated and mildly 64742-65-0 ACGIH Limit value not established: A2: Suspected human treated) carcin., Cntrl all exposr- low as possib PETROLEUM DISTILLATES 64742-65-0 OSHA TWA:2000 mg/m3(500 ppm) Paraffin oil 64742-65-0 OSHA TWA(as mist):5 mg/m3 Mineral oils (untreated and mildly Mixture ACGIH Limit value not established: A2: Suspected human treated) carcin., Cntrl all exposr- low as possib MINERAL OILS, HIGHLY- Mixture Brazil OELs TWA(inhalable fraction)(8 REFINED OILS hours):5 mg/m3 MINERAL OILS, HIGHLY- Mixture ACGIH TWA(inhalable fraction):5 A4: Not class. as human REFINED OILS mg/m3 carcin ACGIH : American Conference of Governmental Industrial Hygienists AIHA : American Industrial Hygiene Association Brazil OELs : Brazil. (NR - 15, Annex 11) Hazardous Chemical Agents for which Occupational Exposure and Inspection Limits have been Established CMRG : Chemical Manufacturer's Recommended Guidelines OSHA : United States Department of Labor - Occupational Safety and Health Administration TWA: Time-Weighted-Average STEL: Short Term Exposure Limit ppm: parts per million mg/m3: milligrams per cubic metre CEIL: Ceiling 8.2. Exposure controls 8.2.1. Engineering controls Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure Limits and/or control dust/fume/gas/mist/vapors/spray. If ventilation is not adequate, use respiratory protection equipment. 8.2.2. Personal protective equipment (PPE) Eye/face protection None required. Skin/hand protection No chemical protective gloves are required. Respiratory protection None required. SECTION 9: Physical and chemical properties 9.1. Information on basic physical and chemical properties Physical state Liquid Appearance/Odor Mild pretroleum odor, clear light amber liquid Odor threshold No Data Available pH No Data Available Melting point/Freezing point Not Applicable Boiling point/Initial boiling point/Boiling range 230 ºC Flash Point 138 ºC [Test Method: Pensky-Martens Closed Cup] Evaporation rate No Data Available Flammability (solid, gas) Not Applicable Flammable Limits(LEL) No Data Available Flammable Limits(UEL) No Data Available Vapor Pressure

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.