Note: Ingredients listed on restricted chemical lists
EC/CAS
9002-84-0
Name of the chemical
Polytetrafluoroethylene
Concentration
100%
General Information
Version
11.01
Revision date
2026-02-15
Product name
3M Dyneon PTFE Micropowder TF 9205
CAS No.
9002-84-0
1.2.1 Relevant identified uses
Fluoropolymer for industrial processing
supplier name
3M Canada Company
Emergency telephone
1800 364 3577
Icons in SDS
Company Information
company name
3M Canada Company
Section 2
SECTION 2: Hazards identification
Classification of the substance or mixture Health Hazards Not Otherwise Classified - Category 1
Health hazards
|
Hazard statements
May cause polymer fume fever.
Prevention
Avoid breathing dust/fume/gas/mist/vapours/spray. In case of inadequate ventilation wear respiratory protection.
Response
IF INHALED Remove person to fresh air and keep comfortable for breathing. If experiencing respiratory symptoms Call a POISON CENTER or doctor.
Disposal
Dispose of contents and container in accordance with applicable local, regional, national, and international regulations.
2.3 Other hazards
May cause thermal burns. vapours liberated during processing may be hazardous if inhaled. Eye, nose, throat and lung irritation can occur from such vapours.
2.1 Classification of the substance or mixture
Health Hazards Not Otherwise Classified - Category 1