Note: Ingredients listed on restricted chemical lists
EC/CAS
14807-96-6
Name of the chemical
Talc
Concentration
N/A
EC/CAS
1333-86-4
Name of the chemical
carbon black
Concentration
N/A
EC/CAS
77-58-7
Name of the chemical
Dibutylzinndilaurat; Dibutyl[bis(dodecanoyloxy)]stannan (2017/776)
Concentration
N/A
EC/CAS
91-08-7
Name of the chemical
2,6-Diisocyanattoluol
Concentration
N/A
EC/CAS
584-84-9
Name of the chemical
2,4-Diisocyanattoluol
Concentration
N/A
General Information
Revision date
2018-09-25
Product name
3M 5000 Detector Loop Sealant, Black
1.2.1 Relevant identified uses
Detector loop sealant (to fill saw cuts after installation of a vehicle detector loop), Detector loop sealant for roadways
supplier name
3M Australia
Emergency telephone
1800 097 146 (Australia only
Icons in SDS
Company Information
company name
3M Australia
e-mail address of the competent person responsible for the Safety Data Sheet
productinfo.au@mmm.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H226, H317, H332, H334, H350, H372
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
SECTION 2: Hazards identification
This product is classified as a hazardous chemical according to the Model Work Health and Safety Regulations, 2011, in accordance with applicable State and Territory legislation. Refer to Section 14 of this Safety Data Sheets for product Dangerous Goods Classification.
2.1 Classification of the substance or mixture
Flammable liquid: Category 3. Acute Toxicity (inhalation): Category 4. Respiratory Sensitizer: Category 1A. Skin Sensitizer: Category 1A. Carcinogenicity: Category 1B. Specific Target Organ Toxicity (repeated exposure): Category 1.
2.2 Label elements
The label elements below were prepared in accordance with the Code of Practice on Preparation of Safety Data Sheets for Hazardous Chemicals (Safe Work Australia, December 2011). This information may be different from the actual product label.
Hazard pictograms
Flame | Exclamation mark | Health Hazard |
Hazard statements
H226 Flammable liquid and vapour. H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. H317 May cause an allergic skin reaction. H332 Harmful if inhaled. H350 May cause cancer. H372 Causes damage to organs through prolonged or repeated exposure: respiratory system |
Prevention
P201 Obtain special instructions before use. P202 Do not handle until all safety precautions have been read and understood. P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking. P240 Ground/bond container and receiving equipment. P242 Use only non-sparking tools. P243 Take precautionary measures against static discharge. P233 Keep container tightly closed. P241 Use explosion-proof electrical/ventilating/lighting equipment. P260 Do not breathe dust/fume/gas/mist/vapours/spray. P261 Avoid breathing dust/fume/gas/mist/vapours/spray. P271 Use only outdoors or in a well-ventilated area. P285 In case of inadequate ventilation wear respiratory protection. P280B Wear protective gloves and eye/face protection. P281 Use personal protective equipment as required. P270 Do not eat, drink or smoke when using this product. P264 Wash thoroughly after handling. P272 Contaminated work clothing should not be allowed out of the workplace.
Response
P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. P304 + P341 IF INHALED: If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. P342 + P311 If experiencing respiratory symptoms: Call a POISON CENTRE or doctor/physician. P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P302 + P352 IF ON SKIN: Wash with plenty of soap and water. P333 + P313 If skin irritation or rash occurs: Get medical advice/attention. P363 Wash contaminated clothing before reuse. P308 + P313 IF exposed or concerned: Get medical advice/attention. P312 Call a POISON CENTRE or doctor/physician if you feel unwell. P370 + P378G In case of fire: Use a fire fighting agent suitable for flammable liquids such as dry chemical or carbon dioxide to extinguish.
Storage
P403 + P235 Store in a well-ventilated place. Keep cool. P405 Store locked up.
Disposal
P501 Dispose of contents/container in accordance with applicable local/regional/national/international regulations. 2.3. Other assigned/identified product hazards Persons previously sensitised to isocyanates may develop a cross-sensitisation reaction to other isocyanates.
Other hazards which do not result in classification
Causes mild skin irritation. Causes eye irritation.