Note: Ingredients listed on restricted chemical lists
EC/CAS
7732-18-5
Name of the chemical
Water, distilled, conductivity or of similar purity H2O
Concentration
N/A
General Information
Revision date
2009-08-12
Product name
3M Overspray Masking Liquid, PN 06834, 06847, 06851, 06856, 06857
CAS No.
7732-18-5
Manufacturer Name
3M
Emergency telephone
1-800-364-3577 or (651) 737-6501 (24 hours
Icons in SDS
Company Information
company name
3M
Section 2
SECTION 2: Hazards identification
OSHA 3.1 EMERGENCY OVERVIEW Specific Physical Form: Viscous Odor, Color, Grade: Ammonia Odor, Red Color General Physical Form: Liquid Immediate health, physical, and environmental hazards:
Potential health effects
Eye Contact: Mild Eye Irritation: Signs/symptoms may include redness, pain, and tearing. Skin Contact: Mild Skin Irritation: Signs/symptoms may include localized redness, swelling, and itching. Inhalation: Respiratory Tract Irritation: Signs/symptoms may include cough, sneezing, nasal discharge, headache, hoarseness, and nose and throat pain. Ingestion: Gastrointestinal Irritation: Signs/symptoms may include abdominal pain, stomach upset, nausea, vomiting and diarrhea. SECTION 4: FIRST AID MEASURES 4.1 FIRST AID PROCEDURES The following first aid recommendations are based on an assumption that appropriate personal and industrial hygiene practices are followed. Eye Contact: Flush eyes with large amounts of water. If signs/symptoms persist, get medical attention. Skin Contact: Wash affected area with soap and water. If signs/symptoms develop, get medical attention. Inhalation: Remove person to fresh air. If signs/symptoms develop, get medical attention. If Swallowed: Do not induce vomiting unless instructed to do so by medical personnel. Give victim two glasses of water. Never give anything by mouth to an unconscious person. Get medical attention. SECTION 5: FIRE FIGHTING MEASURES 5.1 FLAMMABLE PROPERTIES Flash Point > 200 ºF [Test Method: Pensky-Martens Closed Cup] 5.2 EXTINGUISHING MEDIA Ordinary combustible material. Use fire extinguishers with class A extinguishing agents (e.g., water, foam). 5.3 PROTECTION OF FIRE FIGHTERS Special Fire Fighting Procedures: Wear full protective equipment (Bunker Gear) and a self-contained breathing apparatus (SCBA). Unusual Fire and Explosion Hazards: Not applicable. Note: See STABILITY AND REACTIVITY (SECTION 10) for hazardous combustion and thermal decomposition information. SECTION 6: ACCIDENTAL RELEASE MEASURES Accidental Release Measures: Observe precautions from other sections. Call 3M- HELPS line (1-800-364-3577) for more information on handling and managing the spill. Evacuate unprotected and untrained personnel from hazard area. The spill should be cleaned up by qualified personnel. Ventilate the area with fresh air. For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors, in accordance with good industrial hygiene practice. Warning! A motor could be an ignition source and could cause flammable gases or vapors in the spill area to burn or explode. Contain spill. For larger spills, cover drains and build dikes to prevent entry into sewer systems or bodies of water. Working from around the edges of the spill inward, cover with bentonite, vermiculite, or commercially available inorganic absorbent material. Mix in sufficient absorbent until it appears dry. Collect as much of the spilled material as possible. Clean up residue with an appropriate solvent selected by a qualified and authorized person. Ventilate the area with fresh air. Read and follow safety precautions on the solvent label and MSDS. Collect the resulting residue containing solution. Place in a closed container approved for transportation by appropriate authorities. Dispose of collected material as soon as possible. In the event of a release of this material, the user should determine if the release qualifies as reportable according to local, state, and federal regulations. SECTION 7: HANDLING AND STORAGE 7.1 HANDLING Do not eat, drink or smoke when using this product. Wash exposed areas thoroughly with soap and water. Avoid breathing of vapors, mists or spray. Avoid eye contact with vapors, mists, or spray. For industrial or professional use only. Keep out of the reach of children.
Storage
Store in a cool place. Keep from freezing. SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION 8.1 ENGINEERING CONTROLS Use with appropriate local exhaust ventilation. Use with functioning spray booth or local exhaust. Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below Occupational Exposure Limits and/or control mist, vapor, or spray. If ventilation is not adequate, use respiratory protection equipment. 8.2 PERSONAL PROTECTIVE EQUIPMENT (PPE) 8.2.1 Eye/Face Protection Avoid eye contact with vapors, mists, or spray. The following eye protection(s) are recommended: Safety Glasses with side shields, Indirect Vented Goggles. 8.2.2 Skin Protection Select and use gloves and/or protective clothing to prevent skin contact based on the results of an exposure assessment. Consult with your glove and/or protective clothing manufacturer for selection of appropriate compatible materials. Gloves made from the following material(s) are recommended: Neoprene, Nitrile Rubber. 8.2.3 Respiratory Protection Avoid breathing of vapors, mists or spray. Select one of the following NIOSH approved respirators based on airborne concentration of contaminants and in accordance with