Note: Ingredients listed on restricted chemical lists
EC/CAS
98-82-8
Name of the chemical
Cumol (2022/692)
Concentration
0.75%
EC/CAS
91-20-3
Name of the chemical
Naphthalene,3
Concentration
0.6%
General Information
Product name
Dynaflux, Inc
Emergency telephone
1-800-255-3924
Icons in SDS
Company Information
company name
241 Brown Farm Rd., Cartersville, GA 30120 USA
GHS Information
Signal word
Hazard Statement(s
Section 2
2.1 Classification of the substance or mixture
Gas Under Pressure, dissolved Carcinogenicity, category 2
Signal word
Hazard Statement(s) Contains gas under pressure; may explode if heated Suspected of causing cancer Pictogram(s) Precautionary Statements Protect from sunlight. Store in a well-ventilated place Obtain special instructions before use. Do not handle until all safety precautions have been read and understood Wear protective gloves Store locked up Dispose of container in accordance with local regulations IF EXPOSED OR CONCERNED: Get medical advice Hazards not otherwise classified: None known P a g e | 2 0% of the mixture consists of ingredient(s) of unknown acute toxicity Note: Labeling elements found on this SDS may be different from labeling elements found on the label Danger Pictograms Hazards Not Otherwise Classified None Known Note Labeling elements found on this SDS may be different from labeling elements found on the label. Safety Data Sheets Warning
Physical hazards
NFPA®: (higher numbers indicate higher risk) Health Flammability Instability Proposition 65: WARNING! This product contains dichloromethane which is known to the State of California to cause cancer. For more information go to www.P65warnings.ca.gov Other Information Revision Date: May 11, 2021 General Disclaimer: The information presented in this Safety Data Sheet is based on data believed to be accurate as of the date of the l Safety Data sheet was prepared. No responsibility is assumed for any damage or injury resulting from abnormal use or from any failure to adhere to recommended practices as specified on the label copy CRACK CHECK PHF PENETRANT Aerosol – Identification 2 Instability 0
Product definition
Crack Check PHF Penetrant (Aerosol) Other Means of Identification PHF-16 Recommended Use of the Chemical and Restrictions on Use Dye to penetrate cracks in hard surfaces – Hazard Classification Hazard Statement(s) Flammable aerosol Pressurized container: may burst if heated Suspected of causing cancer Suspected of damaging fertility or the unborn child May be fatal if swallowed and enters airways May cause respiratory irritation Causes serious eye irritation Causes skin irritation Precautionary Statement(s) Obtain special instructions before use Do not handle until all safety precautions have been read and understood Keep away from heat, sparks, open flames, and hot surfaces.-No smoking Do not spray on an open flame or other ignition source Do not pierce or burn, even after use Avoid breathing vapors, fume, spray, mist Use only outdoors or in a well-ventilated area Wear protective gloves and eye protection Wash hands and exposed skin thoroughly after handling Dispose of container in accordance with local regulations Store locked up, in a well-ventilated place Protect from sunlight Do not expose to temperatures exceeding 122ºF Keep out of the reach of children IF SWALLOWED: Immediately call a doctor. Do NOT induce vomiting IF ON SKIN: Wash with plenty of water. Take off contaminated clothing and wash it before reuse IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do so. Continue rinsing. If eye irritation persists: Get medical advice IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a doctor if you feel unwell If exposed or concerned: Get medical advice – Information on Ingredients Manufactured For Dynaflux, Inc 241 Brown Farm Rd Cartersville, GA 30120 1.800.334.4420 Emergency Phone Number Call Chem-Tel at 1.800.255.3924 for chemical emergencies Classification of the Chemical Flammable Aerosol, category 2 Aspiration Hazard, category 1 Eye Irritation, category 2A Skin Irritation, category 2 Carcinogenicity, category 2 Reproductive Toxicity, category 2 STOT-SE, category 3 (respiratory) Crack Check PHF Penetrant (Liquid) Other Means of Identification PHF B Recommended Use of the Chemical and Restrictions on Use Dye to penetrate cracks in hard surfaces.
Hazardous Ingredients
Ingredient CAS wt%
Storage
Incompatibilities Oxidizers, acids. Section 8 – Exposure Controls Permissible Exposure Limits Ingredient CAS PEL AGCIH NIOSH 1,2,4-Trimethylbenzene 95-63-6 n/a Solvent Naphtha (petroleum), heavy aromatic 64742-94-5 n/a 2-Naphthalenol, 1-[[4-(phenylazo)phenyl]- azo]-, ar-heptyl ar',ar''-Me derivs. 92257-31-3 n/a Xylene 1330-20-7 100 ppm 20 ppm 100 ppm Hexylene Glycol 107-41-5 25 ppm n/a Cumene 98-82-8 50 ppm Ethylbenzene 100-41-4 100 ppm 20 ppm 100 ppm Naphthalene 91-20-3 10 ppm 📞 1.800.334.4420 info@dynaflux.com dynaflux.com CRACK CHECK PHF PENETRANT November 2024 Aerosol General Note Practice good industrial hygiene by washing hands thoroughly before and after use. Keep working areas clean. Ensure proper use of personal protective equipment as recommended in this section Appropriate Engineering Controls Ensure adequate mechanical ventilation capable of preventing vapor build up Eye & Face Protection Eyeglasses or goggles are recommended when using this product. Eye protection should fit user as to minimize risk of exposure as much as possible. Eye protection should protect against splash back and aerosolized mists which may affect eyes Skin Protection Wear long sleeves and pants to minimize exposure to skin. Wear protective gloves when using this product. Gloves should be chemically resistant to the material. Launder contaminated clothing before reuse. Wear an apron if usage of chemical is anticipated to expose user to a large quantity of material Respiratory Protection Mechanical ventilation is often sufficient for ensuring respiratory systems are better protected against exposure to material; however, should it be determined that material exposure limits are being concentrated as vapors then local ventilation should be utilized. If vapors exceed TLV use an approved respirator. Environmental Protection No anticipated protective equipment is required. Section 9 – Chemical Properties STATE Aerosol, Liquid pH Not determined COLOR Red KINEMATIC VISCOSITY Not determined ODOR Not determined SOLUBILITY Not miscible MELTING POINT Not determined VAPOR PRESSURE Not determined BOILING POINT Not determined RELATIVE DENSITY Not determined FLAMMABILITY Flammable aerosol VAPOR DENSITY 0.08 EXPLOSIVE LIMIT Not determined AUTO-IGNITION TEMP Not determined Upper Not determined DECOMPOSITION TEMP Not determined Lower Not determined PARTITION COEFFICIENT Not determined FLASH POINT Not determined PARTICLE CHARACTERISTICS Not determined Section 10 – Stability and Reactivity Reactivity Conditions to Avoid Material is not anticipated to be reactive Ignition sources, open flames, strong oxidizers Chemical Stability Incompatible Materials Material is anticipated to be stable in normal storage Not determined conditions when not exposed to any incompatible materials Hazardous Decomposition Products Hazardous Reactions Carbon dioxide, carbon monoxide, poisonous gases None known 📞 1.800.334.4420 info@dynaflux.com dynaflux.com CRACK CHECK PHF PENETRANT November 2024 Aerosol
TOXICOLOGICAL INFORMATION
ACUTE TOXICITY ESTIMATES INTERACTIVE EFFECTS Oral – >2,000 mg/kg (non toxic). None known. Dermal – >2,000 m/kg (non toxic). Inhalation – >20.0 mg/L (non toxic). INHALATION EXPOSURE May cause respiratory irritation. SKIN EXPOSURE Not expected to cause a respiratory allergic reaction. Causes serious skin irritation. Not considered toxic to inhalation exposure. Not expected to cause an allergic skin reaction. Not considered toxic to dermal exposure. INGESTION EXPOSURE Aspiration hazard, may be fatal if swallowed and enters EYE EXPOSURE airways. Causes serious eye irritation. REPRODUCTIVE TOXICITY CARCINOGENCITY Not expected to cause germ cell mutations. Suspected of causing cancer Suspected of damaging fertility or the unborn child National Toxicity Listing: Cumene, Naphthalene. International Agency for Research on Cancer Listing: OTHER TOXICITY Xylene (3), Cumene (2B), Ethylbenzene (2B), Naphthalene Not expected to cause drowsiness or dizziness. (2B)
ECOLOGICAL INFORMATION
Ecotoxicity Estimates Bioaccumulative Potential Algae >10 mg/L (not toxic) Not determined Fish >10 mg/L (not toxic) Crustacea >10 mg/L (not toxic)
Other hazards
Not determined Persistence and Degradability Not biodegradable Mobility in Soil Not determined
Disposal
Considerations Disposal of Empty Containers Please recycle container with a licensed recycling company. Disposal of Full or Partially Full Containers Dispose in accordance with all local regulations. Contact a licensed waste management company for questions on disposal procedures. Section 14 – Transportation Information
SECTION 2: Hazards identification
UN Number
1950 Placards UN Shipping Name Aerosol Technical Name n/a Transport Hazard Class 2.2 Flammable Gas Packaging group -
Environmental hazards
Marine Pollutant? Yes Transport in Bulk Not determined Special Precautions Keep in original container. Do not store excessive weight on top Limited Quantity <1L Restrictions 📞 1.800.334.4420 info@dynaflux.com dynaflux.com CRACK CHECK PHF PENETRANT November 2024 Aerosol Section 15 – Regulatory Information
Further information
Revision Reason 1 June 2021 SDS Review and re-authoring 2 Nov 2024
Hazard statements
Flammable liquid and vapor May cause an allergic skin reaction Suspected of causing cancer May cause respiratory irritation Causes serious eye irritation Causes skin irritation
Precautionary statements
Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. In case of fire: Use foam, CO2, or dry chemical to extinguish. Keep away from heat, hot surfaces, sparks, open flames and other ignitions sources. No smoking. Ground or bond container and receiving equipment. Use explosion-proof electrical, ventilating, lighting, and other equipment. Use only non-sparking tools. Take precautionary measures against static discharge. Avoid breathing vapors. Use only outdoors or in a well-ventilated area. Wear protective gloves and eye protection. Wash hands and exposed skin thoroughly after handling. Contaminated work clothing must not be allowed out of the workplace. Dispose of container in accordance with local regulations. Keep container tightly closed. Store locked up. Store in a well-ventilated place. Keep cool. Keep out of the reach of children. IF ON SKIN (or hair): Take off immediately all contaminated clothing. Wash with plenty of water. If skin irritation or rash occurs: Get medical advice. Wash contaminated clothing before reuse. IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a doctor if you feel unwell. Responsible Party Dynaflux, Inc. 241 Brown Farm Rd., Cartersville, GA 30120 1.800.334.4420 Emergency Phone Number Call Chem-Tel at 1.800.255.3924 for chemical emergencies
2.3 Other hazards
None Known Note Labeling elements found on this SDS may be different from labeling elements found on the label. Safety Data Sheets