Note: Ingredients listed on restricted chemical lists
EC/CAS
200-835-2/75-05-8
Name of the chemical
Acetonitrile
Concentration
<9%
EC/CAS
215-609-9/1333-86-4
Name of the chemical
Carbon black
Concentration
<6.5-7%
General Information
Revision date
2021-10-01
Product name
GME Pty Ltd
Product Synonyms
Emergency Position Indicating Beacon (EPIRB), ACCUSATTM
1.2.1 Relevant identified uses
1. The unit is an Emergency Position Indicating Radio Beacon (EPIRB) and is
supplier name
GME Pty Ltd
Emergency telephone
61 2 8867 6000
Icons in SDS
Company Information
company name
17 Gibbon Road, Winston Hills, NSW, 2153, Australia
Section 2
SECTION 2: Hazards identification
· The EPIRB is designed to withstand moderately high levels of shock and vibration consistent with the expected long- term conditions of installation and subsequent deployment. · In an undamaged state the chassis forms an environmentally sealed enclosure which protects the printed circuit board, electronic components and integral battery. · Should the chassis be penetrated then the LiSO2 cells may be exposed to damage and could exhibit the following: - In contact with water releases flammable gases, which may ignite spontaneously – Category 1 - Causes severe skin burns and eye damage – Category 1B - Harmful if swallowed – Category 4 - Harmful if inhaled – Category 4 - Total Lithium content is 4.8g(typ.) per unit. The unit have 1 Battery that consist of 2 cells (2.4g lithium per cell)