GHS08
Health risk rating 5
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

247-852-1/26628-22-8

Name of the chemical

Sodium Azide

Concentration

≤0.09%

General Information

Version

12

Revision date

2019-01-11

Product name

DRI THC (Cannabinoids) Controls and Calibrators, DRI Ecstasy Calibrators

Product Synonyms

100082 DRI Ecstasy 250 ng/mL Calibrator

Chemical name

Mixture

1.2.1 Relevant identified uses

In vitro diagnostic kit Criminal, Forensic, and Justice kits and uses advised against

Emergency telephone

+1 (800) 424-9300, +1 (703) 527-3887, +1 (202) 483-7616

Icons in SDS

GHS08

Company Information

company name

100201 MGC Clinical DAU Control Set

e-mail address of the competent person responsible for the Safety Data Sheet

techservice.mgc@thermofisher.com

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H317, H334

Hazard statements

Code

Statements

H317

May cause an allergic skin reaction

Section 2

SECTION 2: Hazards identification

2.1 Classification of the substance or mixture

substance or mixture Globally Harmonized Respiratory sensitizer - Category 1. Skin sensitizer - Category 1. System [GHS] Other/Supplemental Mixture not yet fully tested

2.2 Label elements

SECTION 2 - HAZARDS IDENTIFICATION …continued

Signal word

Danger

Hazard statements

H317 - May cause allergic skin reaction. H334 - May cause allergy or asthma symptoms or breathing difficulties if inhaled. not be allowed out of the workplace. P280 - Wear protective gloves/eye protection/ face protection. P285 - In case of inadequate ventilation wear respiratory protection. P302 + P352 - IF ON SKIN: Wash with plenty of soap and water. P304 + P341 - IF INHALED: If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. P333 + P313 - If skin irritation or rash occurs: Get medical advice/attention. P342 + P311 - If experiencing respiratory symptoms: Call a POISON CENTER or doctor/physician. P363 - Wash contaminated clothing before reuse. P501 - Dispose of contents/container to location in accordance with local/regional/national/international regulations.

Precautionary statements

P261 - Avoid breathing mist or vapor. P272 - Contaminated work clothing should

2.3 Other hazards

The potential health hazards associated with exposure/handling of this mixture are unknown; no data specific for the mixture were identified. The following data describe the hazards of individual ingredients, where applicable. This product/mixture contains human urine and should be treated/handled as a potential biohazard. All such human urine has been derived from donors tested individually and shown by FDA approved methods to be free from antibodies to Human Immune Deficiency Virus and Hepatitis B and C. As no test method can offer complete assurance that these or other infectious agents are not present, this product should be handled using standard biosafety precautions. The mixture contains bovine serum albumin which has been associated with occupational sensitization. Material produced in compliance with USDA and/or CPMP/BWP/1230/98 (Guidance on Minimizing the Risk of Transmitting Animal Spongiform Encephalopathy Agents via Medicinal Products). This is a CPMP/ BWP/1230/98 Category IV material: it does not contain nor is it derived from specified risk materials as defined in Commission decision 97/534/EC (or successive amendments). Because the mixture contains a protein (bovine serum albumin) it may cause an allergic skin or respiratory reaction (e.g., potential to cause anaphylaxis). In a workplace setting, the likelihood of systemic effects following accidental ingestion is low, due to the rapid breakdown of proteins in the digestive tract. Proteins, in general, can cause skin and/or respiratory sensitization. Note This mixture is classified as hazardous under GHS as implemented by Regulation

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.