Note: Ingredients listed on restricted chemical lists
EC/CAS
25322-68-3
Name of the chemical
polyethyleneglycol
Concentration
1.5μL/L
EC/CAS
67-56-1
Name of the chemical
Methanol
Concentration
500mL/L
EC/CAS
7732-18-5
Name of the chemical
Water, distilled, conductivity or of similar purity H2O
Concentration
500mL/L
General Information
MSDS DATE
2017-11-02
Name of the product
LCMS 2010 Tune Solution
1.5 Product Use:
For LCMS equipment evaluation
Manufacturer Name
SHIMADZU SCIENTIFIC INSTRUMENTS, INC
Emergency Contact
(800) 477-1227
Icons in SDS
Company Information
Company Name
SHIMADZU SCIENTIFIC INSTRUMENTS, INC
GHS Information
Signal word
סַכָּנָה
Hazard Codes
Hazard statements (CLP)
H225, H301, H311, H331, H370
Section 2
חלק 2 :סיכוני החומר המסוכן
Pictograms
DANGER
Hazard statements
H225 Highly flammable liquid and vapour H331 Toxic if inhaled H311 Toxic in contact with skin H301 Toxic if swalloed H370 Causes damage to organs
Precautionary statements
P210 Keep away from ignition sources such as heat/sparks/open flame. -No smoking. P260 Do not breathe dust/fume/gas/mist/vapours/spray. P280 Wear protective gloves/protective clothing. P301+P310 IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician. P311 Call a POISON CENTER or doctor/physician.
#2_1_1_1_2_CLASSIFICATION_DSD
Hazrd symbols F -Highly famable T -Toxic
#2_2_5_R_PHRASES
F-R11 T-R23/425-R39/234/25 ―――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――